Skip to content

nVent ILSCO SK-350 CU Tin-Plated Copper Split-Bolt Connector

0 Reviews
SKU
SK-350 CU

The nVent ILSCO SK-350 CU is a mechanical, two-conductor split-bolt connector made of tin-plated copper. It is specified for conductor splicing and tapping, with equal stranded main-and-tap conductors listed from 3/0 AWG through 350 MCM and equal 4/0 AWG solid conductors.

  • Equal Stranded Main/Tap Range
  • Equal Solid Conductor Size
  • Tin-Plated Copper Construction
  • Copper and Copperweld Compatibility
  • 35 kV Voltage Rating
  • UL Listed, CSA Marked

The nVent ILSCO SK-350 CU is a mechanical, two-conductor split-bolt connector made of tin-plated copper. It is specified for conductor splicing and tapping, with equal stranded main-and-tap conductors listed from 3/0 AWG through 350 MCM and equal 4/0 AWG solid conductors.

Product Overview

The nVent ILSCO SK-350 CU is a mechanical, two-conductor split-bolt connector made of tin-plated copper. It is specified for conductor splicing and tapping, with equal stranded main-and-tap conductors listed from 3/0 AWG through 350 MCM and equal 4/0 AWG solid conductors.

  • Equal Stranded Main/Tap Range
  • Equal Solid Conductor Size
  • Tin-Plated Copper Construction
  • Copper and Copperweld Compatibility
  • 35 kV Voltage Rating
  • UL Listed, CSA Marked

Technical Specifications

Product information and specifications for the selected item.

SKU: SK-350 CU

Product Information

BrandnVent ILSCO
MPNSK-350 CU
SKUSK-350 CU
CategoryTerminals, Splices & Connectors

Key Specs

Wire Connector TypeSplicer
Minimum Wire Gauge1
Color FamilySilver
Length (in.)2.63

Connector & Wire

Wire Connector TypeSplicer
Minimum Wire Gauge1
Maximum CU stranded conductor size350 kcmil
Compatible conductor combinationsCopper to copper; Copperweld to Copperweld; Copper to Copperweld
Voltage rating35 kV
Maximum equal-run/tap ACSR size336.4 ACSR
Maximum stranded Copperweld conductor19 No. 7
Connection methodMechanical
Stripping timing for insulated wireFor insulated wire rated 90°C maximum in NEC applications, strip immediately before installation.
CSA markingCSA mark, 701570
Tap size with one maximum-size main1 SOL
Strand damage warningNicking wire strands reduces the wire's current-carrying capacity.
MaterialCopper
Installation torque650 in-lb
Conductor surface preparationClean conductor surfaces with a wire brush or abrasive cloth; apply anti-oxidant to stripped ends and brush it into the strands.
Maximum equal main-and-tap conductor size350 kcmil
Temperature rating90 °C
Torque warningFailure to achieve proper torque can cause connector and wire overheating.
Splice connection procedureInsert splice wires through opposite sides to full clamp contact; hand-tighten, then torque to the specified value.
Spacer positioningThe additional spacer must be clamped between the two wires, with its radius side facing the nut/pressure bar.
Insulation strippingStrip for proper clamp contact without insulation overlap or nicking strands; use an appropriate stripping tool or the pencil-shaving method.
Equal-run/tap solid conductor size4/0 Sol
Wire diameter range0.447-0.682 in
Tap connection procedureFor a tap, remove the nut/pressure bar and spacer, position the connector over the main wire, reinstall the spacer and nut/pressure bar, insert the tap for full clamp contact, then hand-tighten before torquing.
UL listingUL-listed wire connector, 460C

Color & Finish

Color FamilySilver
Connector finishTin

Dimensions & Weight

Height (in.)1.63
Width (in.)1.88
Length (in.)2.63
Weight (lb.)0.766

Product Documents

  • Copper Split Bolt Connectors — Installation Instructions (Form 165) Installation manual Open / download file

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.