Skip to content
Priority Wire & Cable

444/1 DLO

0 Reviews
SKU
444-01DLO

Priority Wire & Cable 444-01DLO is 444.4 kcmil DLO cable with a 2,000 V maximum application voltage and 656 A ampacity for one conductor in free air at 30°C ambient and 90°C conductor temperature. It has a flexible Class I tinned-copper conductor, EPR insulation, and a black thermoset CPE jacket; it is cut by the foot.

  • 444.4 kcmil conductor size
  • 2,000 V maximum application voltage
  • 656 A ampacity in free air
  • Flexible Class I tinned-copper conductor
  • EPR insulation
  • Black thermoset CPE jacket

Product Overview

Priority Wire & Cable 444-01DLO is 444.4 kcmil DLO cable with a 2,000 V maximum application voltage and 656 A ampacity for one conductor in free air at 30°C ambient and 90°C conductor temperature. It has a flexible Class I tinned-copper conductor, EPR insulation, and a black thermoset CPE jacket; it is cut by the foot.

Technical Specifications

Product information and specifications for the selected item.

SKU: 444-01DLO

Product Information

BrandPriority Wire & Cable
MPN444-01DLO
SKU444-01DLO
CategoryPortable Cord

Cable & Conductor

Tray cable ratingRW90-TC rated for TC use on sizes 1/0 and larger
CSA listingRW90 and RW90-TC listed at 1 kV
Conductor standardsASTM B-172, B-174, and B-33
MSHA approvalApproved
Flame ratingVW-1
Nominal insulation thickness0.090 in
UL cable classificationRHH/RHW-2 per UL 44
Maximum application voltageUp to 2,000 V
Operating temperature range-40 to +90 °C
Smoke and flame ratingLimited Smoke ST1 in accordance with UL 1685 vertical flame test
CSA standardsCSA C22.2 No. 38 and No. 230
Insulation materialEthylene-propylene rubber (EPR), specified per UL, CSA, ICEA, and AAR RP-588
Installation environmentSuitable for wet and dry areas, conduits, ducts, troughs, and trays
RP approvalsRP-588 and RP-586 approved
Additional applicationsTelecom power supply, shipyards, motor leads, mining and earth-moving equipment, and oil and gas rigs
Conductor constructionFully annealed, flexible Class I stranded
UL designationRHH/RHW-2 per UL 44
Suitable environmentsSuitable for wet and dry areas
CT-use ratingFor CT use; ST-1, FT-4, and IEEE 1202 apply to sizes 1/0 and larger
Ampacity656 at 30°C ambient; single conductor in free air with 90°C conductor temperature
Separator constructionTape separator between conductor and insulation
Conductor stranding1091/24 No./AWG

Length & Jacket

Wire Cut TypeCut By-The-Foot
Jacket ColorBlack
Nominal jacket thickness0.065 in
Jacket material and resistanceHeavy-duty thermoset CPE; resistant to ozone, sunlight, oil, grease, weather, chemicals, and abrasion

Dimensions & Weight

Height (in.)1.169
Width (in.)1.169

Other Specifications

Conductor MaterialTinned Copper