The Reliance Controls Pro/Tran 2 510A is a 50 A, single-phase indoor manual transfer switch with 10 circuits, a 12,500 W maximum, and a non-NEMA CS6375 turn-to-lock inlet. It includes two watt meters and a powder-coated steel enclosure.
The Reliance Controls Pro/Tran 2 510A is a 50 A, single-phase indoor manual transfer switch with 10 circuits, a 12,500 W maximum, and a non-NEMA CS6375 turn-to-lock inlet. It includes two watt meters and a powder-coated steel enclosure.
The Reliance Controls Pro/Tran 2 510A is a 50 A, single-phase indoor manual transfer switch with 10 circuits, a 12,500 W maximum, and a non-NEMA CS6375 turn-to-lock inlet. It includes two watt meters and a powder-coated steel enclosure.
Product information and specifications for the selected item.
| Brand | Reliance Controls |
|---|---|
| MPN | 510A |
| SKU | 510A |
| UPC / GTIN | 815181012137 |
| Category | Manual Transfer Switches |
| Maximum Amperage (A) | 50 |
|---|---|
| Maximum Wattage (W) | 12500 |
| Automatic/Manual | Manual |
| Certifications and Listings | UL Listed |
| Maximum Amperage (A) | 50 |
|---|---|
| Maximum Wattage (W) | 12500 |
| Minimum cord gauge | 6 AWG |
| Circuit-breaker position compatibility | All positions accept 15 and 20; only positions A and B accept 30 |
| Minimum recommended cord size | 6 gauge |
| 240 V circuit compatibility | Any two adjacent selector switches can serve a double-pole 240 V circuit when connected with a handle tie; positions used for multi-wire branch circuits are not available for 240 V circuits. |
| Maximum double-pole and multi-wire circuits | 5 circuits |
| Factory-wired circuit arrangement | Factory-wired combination of 120V and 240V circuits |
| Cord conductors | 4 conductors |
| Power inlet configuration | CS6375, non-NEMA |
| Neutral switching and generator compatibility | Two-pole switch; does not switch neutral; intended for a generator with floating neutral (ground and neutral not bonded). |
| Maximum generator-circuit load distribution | 2 circuits at 30; 8 circuits at 20 A per circuit |
| Generator input voltage | 125/250 V |
| Power inlet connection style | Turn-to-lock (CS6375) |
| Automatic/Manual | Manual |
|---|---|
| Features | Mountable, On/Off Switch |
| Cabinet material and finish | Powder-coated steel |
| Mounting style | Surface-mount |
| Wattmeter operating condition | Meters register only when generator power is being used. |
| Handle ties provided | 2 ties |
| Load-center placement | May be installed on either side of the load center. |
| NEMA enclosure type | 1 |
| Wattmeter circuit coverage | Left meter covers circuits A, C, E, G, I; right meter covers B, D, F, H, J. |
| Outdoor installation condition | If this indoor model is installed outdoors, install it in a dry location. |
| AFCI/GFCI behavior in generator mode | AFCI/GFCI protection is lost in GEN position unless appropriate breakers are installed in the transfer switch. |
| Certifications and Listings | UL Listed |
|---|
| Height (in.) | 11.25 |
|---|---|
| Width (in.) | 11.75 |
| Length (in.) | 4.5 |
| Weight (lb.) | 16.05 |
| Conduit trade-size diameter | 1 in |
| Flexible conduit length | 18 in |