Schneider Electric TeSys Deca LC1D18M is an 18 A lighting contactor with three normally open poles, non-reversing operation, a 220 VAC coil, and a stated 600 VAC rating. Its listed applications include resistive loads and motor control.
Schneider Electric TeSys Deca LC1D18M is an 18 A lighting contactor with three normally open poles, non-reversing operation, a 220 VAC coil, and a stated 600 VAC rating. Its listed applications include resistive loads and motor control.
Schneider Electric TeSys Deca LC1D18M is an 18 A lighting contactor with three normally open poles, non-reversing operation, a 220 VAC coil, and a stated 600 VAC rating. Its listed applications include resistive loads and motor control.
Product information and specifications for the selected item.
| Brand | Schneider Electric |
|---|---|
| MPN | LC1D18M |
| SKU | LC1D18M |
| Category | Lighting Contactors |
| Number of Poles | 3 |
|---|---|
| Coil Voltage | 220 VAC |
| Contact Type | N.O. |
| Number of Poles | 3 |
|---|---|
| Coil Voltage | 220 VAC |
| Contact Type | N.O. |
| Terminal tightening torque | 1.7; screwdriver flat Ø 6 mm, Philips No 2 or Pozidriv No 2 N.m |
| Protection and protective treatment | IP20 front face; protective treatment TH; protective cover included |
| Contactor application | Resistive load; motor control |
| Rated short-time withstand current | Power circuit: 145 A for 10 s, 240 A for 1 s, 40 A for 10 min, and 84 A for 1 min (at 40 °C); signalling circuit: 100 A for 1 s, 120 A for 500 ms, 140 A for 100 ms |
| Ambient temperature and operating altitude | -40...60 °C; 60...70 °C with derating; altitude 0...3000 m |
| Operating time and maximum operating rate | Closing: 12...22 ms; opening: 4...19 ms; maximum rate: 3600 cycles/h at 60 °C |
| Auxiliary contact construction | 1 NO + 1 NC auxiliary contacts, mechanically linked; 1 NC mirror contact |
| Rated impulse withstand voltage | 6 kV |
| Rated insulation voltage | Power circuit: 690 V IEC; 600 V CSA and UL. Signalling circuit: 690 V IEC; 600 V CSA and UL. |
| Utilisation categories | AC-1, AC-4, AC-3, AC-3e |
| Rated breaking capacity | 300 A at 440 V for the power circuit |
| Rated making capacity | Signalling: 140 A AC and 250 A DC; power circuit: 300 A at 440 V |
| Control circuit consumption and coil construction | Inrush: 70 VA at 50/60 Hz (cos phi 0.75, 20 °C); hold-in: 7 VA at 50 Hz or 7.5 VA at 60 Hz (cos phi 0.3, 20 °C); heat dissipation: 2...3 W at 50/60 Hz; no built-in suppressor module. |
| Durability and safety reliability | Mechanical durability: 15 Mcycles; electrical durability: 1.65 Mcycles at 18 A AC-3 and AC-3e (Ue <=440 V), 1 Mcycles at 32 A AC-1 (Ue <=440 V); B10d: 1369863 cycles at nominal load and 20000000 cycles with mechanical load. |
| Rated operational voltage | Power circuit: ≤690 V AC at 25–400 Hz; ≤300 V DC |
| Standards and product certifications | Standards: CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1. Certifications: UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme. |
| Overvoltage category and pollution degree | Overvoltage category III; pollution degree 3 |
| Power circuit terminal conductor sizes | Without cable ends: 1 or 2 conductors, 1.5...6 mm² (flexible or solid); with cable ends (flexible): 1 conductor, 1...6 mm²; 2 conductors, 1...4 mm². |
| Associated fuse rating | Power: 50 A gG at <=690 V for coordination type 1; 35 A gG at <=690 V for coordination type 2. Signalling: 10 A gG. |
| Rated operational current by category | AC-3: 18 A; AC-1: 32 A; AC-3e: 18 A (all at <=440 V AC and <60 °C); AC-4: 9.75 A at <=690 V AC (<60 °C). Conventional free-air thermal current at 60 °C: 32 A power circuit, 10 A signalling circuit. |
| Motor power ratings | AC-3: 4 kW at 220...230 V AC; 7.5 kW at 380...400 V AC; 9 kW at 415...440 V AC; 10 kW at 500 V AC and 660...690 V AC (50/60 Hz). Three-phase motor ratings: 10 hp at 460/480 V AC and 15 hp at 575/600 V AC (50/60 Hz). |
| Signalling circuit switching characteristics | 25...400 Hz signalling frequency; minimum switching voltage 17 V; minimum switching current 5 mA; insulation resistance >10 MOhm; NC/NO non-overlap 1.5 ms on energisation and de-energisation |
| Mechanical and fire robustness | Vibration: contactor open 2 Gn and closed 4 Gn at 5...300 Hz; shock: open 10 Gn and closed 15 Gn for 11 ms; fire resistance 850 °C; flame retardance V1 |
|---|---|
| Mounting support | Plate; rail |