Schneider Electric TeSys Deca LC1D18M is an 18 A lighting contactor with three normally open poles, non-reversing operation, a 220 VAC coil, and a stated 600 VAC rating. Its listed applications include resistive loads and motor control.

  • 18 A contactor rating
  • Three normally open poles
  • 220 VAC coil
  • Non-reversing operation
  • 600 VAC rating
  • 1 NO + 1 NC auxiliary pair

Schneider Electric TeSys Deca LC1D18M is an 18 A lighting contactor with three normally open poles, non-reversing operation, a 220 VAC coil, and a stated 600 VAC rating. Its listed applications include resistive loads and motor control.

Product Overview

Schneider Electric TeSys Deca LC1D18M is an 18 A lighting contactor with three normally open poles, non-reversing operation, a 220 VAC coil, and a stated 600 VAC rating. Its listed applications include resistive loads and motor control.

  • 18 A contactor rating
  • Three normally open poles
  • 220 VAC coil
  • Non-reversing operation
  • 600 VAC rating
  • 1 NO + 1 NC auxiliary pair

Technical Specifications

Product information and specifications for the selected item.

SKU: LC1D18M

Product Information

BrandSchneider Electric
MPNLC1D18M
SKULC1D18M
CategoryLighting Contactors

Key Specs

Number of Poles3
Coil Voltage220 VAC
Contact TypeN.O.

Switching & Electrical

Number of Poles3
Coil Voltage220 VAC
Contact TypeN.O.
Terminal tightening torque1.7; screwdriver flat Ø 6 mm, Philips No 2 or Pozidriv No 2 N.m
Protection and protective treatmentIP20 front face; protective treatment TH; protective cover included
Contactor applicationResistive load; motor control
Rated short-time withstand currentPower circuit: 145 A for 10 s, 240 A for 1 s, 40 A for 10 min, and 84 A for 1 min (at 40 °C); signalling circuit: 100 A for 1 s, 120 A for 500 ms, 140 A for 100 ms
Ambient temperature and operating altitude-40...60 °C; 60...70 °C with derating; altitude 0...3000 m
Operating time and maximum operating rateClosing: 12...22 ms; opening: 4...19 ms; maximum rate: 3600 cycles/h at 60 °C
Auxiliary contact construction1 NO + 1 NC auxiliary contacts, mechanically linked; 1 NC mirror contact
Rated impulse withstand voltage6 kV
Rated insulation voltagePower circuit: 690 V IEC; 600 V CSA and UL. Signalling circuit: 690 V IEC; 600 V CSA and UL.
Utilisation categoriesAC-1, AC-4, AC-3, AC-3e
Rated breaking capacity300 A at 440 V for the power circuit
Rated making capacitySignalling: 140 A AC and 250 A DC; power circuit: 300 A at 440 V
Control circuit consumption and coil constructionInrush: 70 VA at 50/60 Hz (cos phi 0.75, 20 °C); hold-in: 7 VA at 50 Hz or 7.5 VA at 60 Hz (cos phi 0.3, 20 °C); heat dissipation: 2...3 W at 50/60 Hz; no built-in suppressor module.
Durability and safety reliabilityMechanical durability: 15 Mcycles; electrical durability: 1.65 Mcycles at 18 A AC-3 and AC-3e (Ue <=440 V), 1 Mcycles at 32 A AC-1 (Ue <=440 V); B10d: 1369863 cycles at nominal load and 20000000 cycles with mechanical load.
Rated operational voltagePower circuit: ≤690 V AC at 25–400 Hz; ≤300 V DC
Standards and product certificationsStandards: CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1. Certifications: UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme.
Overvoltage category and pollution degreeOvervoltage category III; pollution degree 3
Power circuit terminal conductor sizesWithout cable ends: 1 or 2 conductors, 1.5...6 mm² (flexible or solid); with cable ends (flexible): 1 conductor, 1...6 mm²; 2 conductors, 1...4 mm².
Associated fuse ratingPower: 50 A gG at <=690 V for coordination type 1; 35 A gG at <=690 V for coordination type 2. Signalling: 10 A gG.
Rated operational current by categoryAC-3: 18 A; AC-1: 32 A; AC-3e: 18 A (all at <=440 V AC and <60 °C); AC-4: 9.75 A at <=690 V AC (<60 °C). Conventional free-air thermal current at 60 °C: 32 A power circuit, 10 A signalling circuit.
Motor power ratingsAC-3: 4 kW at 220...230 V AC; 7.5 kW at 380...400 V AC; 9 kW at 415...440 V AC; 10 kW at 500 V AC and 660...690 V AC (50/60 Hz). Three-phase motor ratings: 10 hp at 460/480 V AC and 15 hp at 575/600 V AC (50/60 Hz).
Signalling circuit switching characteristics25...400 Hz signalling frequency; minimum switching voltage 17 V; minimum switching current 5 mA; insulation resistance >10 MOhm; NC/NO non-overlap 1.5 ms on energisation and de-energisation

Dimensions & Weight

Mechanical and fire robustnessVibration: contactor open 2 Gn and closed 4 Gn at 5...300 Hz; shock: open 10 Gn and closed 15 Gn for 11 ms; fire resistance 850 °C; flame retardance V1
Mounting supportPlate; rail