Schneider Electric TeSys Deca GV2ME21 is a three-pole thermal-magnetic motor circuit breaker with an adjustable 17–23 A current range. It is rated 690 V AC and has screw-clamp terminals, push-button control, and DIN-rail mounting.

  • Adjustable 17–23 A Range
  • 3-Pole Motor Circuit Breaker
  • 690 V AC Rating
  • Screw-Clamp Terminals
  • DIN-Rail Mounting
  • Push-Button Control

Schneider Electric TeSys Deca GV2ME21 is a three-pole thermal-magnetic motor circuit breaker with an adjustable 17–23 A current range. It is rated 690 V AC and has screw-clamp terminals, push-button control, and DIN-rail mounting.

Product Overview

Schneider Electric TeSys Deca GV2ME21 is a three-pole thermal-magnetic motor circuit breaker with an adjustable 17–23 A current range. It is rated 690 V AC and has screw-clamp terminals, push-button control, and DIN-rail mounting.

  • Adjustable 17–23 A Range
  • 3-Pole Motor Circuit Breaker
  • 690 V AC Rating
  • Screw-Clamp Terminals
  • DIN-Rail Mounting
  • Push-Button Control

Technical Specifications

Product information and specifications for the selected item.

SKU: GV2ME21

Product Information

BrandSchneider Electric
MPNGV2ME21
SKUGV2ME21
UPC / GTIN3389110343212
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)23
Voltage690 V AC
Interruption TypeStandard Trip
Mounting TypeDin Rail
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)23
Voltage690 V AC
Interruption TypeStandard Trip
Operating ambient temperature-20 to +60 °C
Motor power rating11 at 500 V AC; 9 at 400/415 V AC; 18.5 at 690 V AC, 50/60 Hz kW
Restart after overload tripAfter a trip following motor overload, do not restart until the motor has cooled completely.
Storage temperature-40 to +80 °C
Operating rate25 cycles/h
Impact protection ratingIK04
Rated service short-circuit breaking capacity (Ics)100 at 230/240 V AC; 40 at 400/415 V AC; 50 at 440 V AC; 75 at 500 V AC; 75 at 690 V AC (50/60 Hz) %
Maximum operating altitude2000 m
Rated impulse withstand voltage6 kV
Phase-failure sensitivityYes, conforming to IEC 60947-4-1
Magnetic tripping current327 A
Power dissipation per pole2.5 W
IP protection ratingIP20, conforming to IEC 60529
Network frequency50/60 Hz
Utilisation categoryAC-3; Category A
Ultimate short-circuit breaking capacity (Icu)3 at 690 V AC; 15 at 400/415 V AC; 50 at 230/240 V AC; 6 at 440 V AC; 4 at 500 V AC (50/60 Hz) kA
Suitability for isolationYes, conforming to IEC 60947-1
Mechanical and electrical durability100,000 mechanically; 100,000 electrically for AC-3 at 440 V cycles

Breaker Configuration

Mounting TypeDin Rail
Neutral Connection TypeNon-Neutral
Series TypeTeSys GV2
Terminal tightening torque1.7 N·m
Mounting positionHorizontal or vertical
Conductor strip length10 (3/8 in.) mm
Supported conductor sizes and typesTwo cables: solid 1–6 mm²; flexible without cable end 1.5–6 mm²; flexible with cable end 1–4 mm²
Ex-application configurationFor Ex applications, configuration must be performed by qualified, trained service personnel; match thermal class and motor current to the protected motor.

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsCSA Certified, ROHS, UL Certified
Explosive-atmosphere use conditionsWhen bearing the specified Ex marking, use for protection of explosion-protected motors in Zones 1–2 or 21–22; install the breaker outside Ex zones.

Dimensions & Weight

Height (in.)3.5
Width (in.)1.77
Length (in.)3.09
Weight (lb.)0.57