| Brand | Schneider Electric |
|---|---|
| MPN | GV2ME21 |
| SKU | GV2ME21 |
| UPC / GTIN | 3389110343212 |
| Category | Circuit Breakers |
| Maximum Amperage (A) | 23 |
|---|---|
| Voltage | 690 V AC |
| Interruption Type | Standard Trip |
| Mounting Type | Din Rail |
| Neutral Connection Type | Non-Neutral |
| Maximum Amperage (A) | 23 |
|---|---|
| Voltage | 690 V AC |
| Interruption Type | Standard Trip |
| Operating ambient temperature | -20 to +60 °C |
| Motor power rating | 11 at 500 V AC; 9 at 400/415 V AC; 18.5 at 690 V AC, 50/60 Hz kW |
| Restart after overload trip | After a trip following motor overload, do not restart until the motor has cooled completely. |
| Storage temperature | -40 to +80 °C |
| Operating rate | 25 cycles/h |
| Impact protection rating | IK04 |
| Rated service short-circuit breaking capacity (Ics) | 100 at 230/240 V AC; 40 at 400/415 V AC; 50 at 440 V AC; 75 at 500 V AC; 75 at 690 V AC (50/60 Hz) % |
| Maximum operating altitude | 2000 m |
| Rated impulse withstand voltage | 6 kV |
| Phase-failure sensitivity | Yes, conforming to IEC 60947-4-1 |
| Magnetic tripping current | 327 A |
| Power dissipation per pole | 2.5 W |
| IP protection rating | IP20, conforming to IEC 60529 |
| Network frequency | 50/60 Hz |
| Utilisation category | AC-3; Category A |
| Ultimate short-circuit breaking capacity (Icu) | 3 at 690 V AC; 15 at 400/415 V AC; 50 at 230/240 V AC; 6 at 440 V AC; 4 at 500 V AC (50/60 Hz) kA |
| Suitability for isolation | Yes, conforming to IEC 60947-1 |
| Mechanical and electrical durability | 100,000 mechanically; 100,000 electrically for AC-3 at 440 V cycles |
| Mounting Type | Din Rail |
|---|---|
| Neutral Connection Type | Non-Neutral |
| Series Type | TeSys GV2 |
| Terminal tightening torque | 1.7 N·m |
| Mounting position | Horizontal or vertical |
| Conductor strip length | 10 (3/8 in.) mm |
| Supported conductor sizes and types | Two cables: solid 1–6 mm²; flexible without cable end 1.5–6 mm²; flexible with cable end 1–4 mm² |
| Ex-application configuration | For Ex applications, configuration must be performed by qualified, trained service personnel; match thermal class and motor current to the protected motor. |
| Bundle/Single | Single Product |
|---|---|
| Pack Options | Single Item |
| Certifications and Listings | CSA Certified, ROHS, UL Certified |
|---|---|
| Explosive-atmosphere use conditions | When bearing the specified Ex marking, use for protection of explosion-protected motors in Zones 1–2 or 21–22; install the breaker outside Ex zones. |
| Height (in.) | 3.5 |
|---|---|
| Width (in.) | 1.77 |
| Length (in.) | 3.09 |
| Weight (lb.) | 0.57 |