Skip to content
Schneider Electric

Schneider Electric TeSys Deca LRD14 Thermal Overload Relay, 7–10A, Manual Reset

0 Reviews
SKU
LRD14

Schneider Electric’s TeSys Deca LRD14 is a three-pole thermal overload relay with an adjustable 7–10 A trip range, manual reset, and one normally open plus one normally closed auxiliary contact. It is listed for 690 V AC and DIN-rail mounting.

  • Adjustable 7–10 A trip range
  • Three-pole thermal overload relay
  • Compatible LC1D contactors
  • Manual reset
  • 1 NO + 1 NC auxiliary contacts
  • 690 V AC voltage

Schneider Electric’s TeSys Deca LRD14 is a three-pole thermal overload relay with an adjustable 7–10 A trip range, manual reset, and one normally open plus one normally closed auxiliary contact. It is listed for 690 V AC and DIN-rail mounting.

Product Overview

Schneider Electric’s TeSys Deca LRD14 is a three-pole thermal overload relay with an adjustable 7–10 A trip range, manual reset, and one normally open plus one normally closed auxiliary contact. It is listed for 690 V AC and DIN-rail mounting.

  • Adjustable 7–10 A trip range
  • Three-pole thermal overload relay
  • Compatible LC1D contactors
  • Manual reset
  • 1 NO + 1 NC auxiliary contacts
  • 690 V AC voltage

Technical Specifications

Product information and specifications for the selected item.

SKU: LRD14

Product Information

BrandSchneider Electric
MPNLRD14
SKULRD14
UPC / GTIN3389110346817
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)10
Voltage690 V AC
Mounting TypeDin Rail

Electrical Ratings

Maximum Amperage (A)10
Voltage690 V AC
Tripping threshold1.14 ± 0.06 × Ir, per IEC 60947-4-1
Network frequency range0 to 400 Hz
Conventional free-air thermal current5 A for the signalling circuit
Phase-failure sensitivityTripping current is 130% of Ir on two phases; the last phase at 0
Network typeAC or DC
Associated fuse rating4 A gG or 4 A BS for the signalling circuit
Auxiliary-contact permissible current3 A at 120 V AC-15; 0.22 A at 125 V DC-13, for the signalling circuit

Breaker Configuration

Mounting TypeDin Rail
Series TypeTeSys Deca
Power-circuit conductor sizes1.5–10 mm² flexible without cable end; 1–4 mm² flexible with cable end; 1–6 mm² solid without cable end
Control-circuit terminal conductor capacityScrew-clamp terminals: flexible conductors 1–2.5 mm² with or without cable end; solid conductors 1–2.5 mm² without cable end
Auxiliary contact composition1 normally open (NO) + 1 normally closed (NC)
Compatible contactorsLC1D09, LC1D12, LC1D38, LC1D32, LC1D25, LC1D18
Control buttonsRed push-button for stop; blue push-button for reset
Power-circuit terminal conductor capacityScrew-clamp terminals: flexible conductors 1.5–10 mm² without cable end; flexible 1–4 mm² with cable end; solid 1–6 mm² without cable end
Control-circuit conductor sizes1–2.5 mm² for flexible conductors with or without cable end, or solid conductors
Terminal tightening torque1.7 N·m for control- and power-circuit screw-clamp terminals
Restart after overload tripAfter a motor-overload trip, do not restart until the motor has cooled completely.

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsCSA Certified, ROHS, UL Certified
Storage temperature−60 to 70 (equivalent to −76 to 158 °F) °C
Mechanical robustnessVibration: 6 Gn; shock: 15 Gn for 11 ms
Degree of protectionIP20, conforming to IEC 60529
REACH substance statusNo REACH Annex XVII restricted substances are used in scope; no SVHC above 0.1% at part level.
Ambient operating temperature−20 to 60 (without derating, IEC 60947-4-1; equivalent to −4 to 140 °F) °C
Flame retardanceV1, conforming to UL 94
Explosive-atmosphere installation conditionsFor covered LRD differential class 10A variants bearing the specified Ex marking, install the relay outside Ex zones; it is qualified to protect explosion-protected motors in Zones 1–2 or 21–22.
Climatic withstandIACS E10

Dimensions & Weight

Height (in.)2.6
Width (in.)1.77
Length (in.)2.76
Weight (lb.)0.273

Product Documents