The Schneider Electric TeSys Deca LRD21 is an adjustable thermal overload relay for motor protection, with a 12–18 A current range and Class 10A trip class. It is specified for use with LC1D18, LC1D25, LC1D32, and LC1D38 contactors.

  • Adjustable 12–18 A range
  • LC1D contactor compatibility
  • Class 10A trip class
  • Phase-failure trip response
  • 690 V AC / 250 V DC ratings
  • 1 NO + 1 NC auxiliary contacts

The Schneider Electric TeSys Deca LRD21 is an adjustable thermal overload relay for motor protection, with a 12–18 A current range and Class 10A trip class. It is specified for use with LC1D18, LC1D25, LC1D32, and LC1D38 contactors.

Product Overview

The Schneider Electric TeSys Deca LRD21 is an adjustable thermal overload relay for motor protection, with a 12–18 A current range and Class 10A trip class. It is specified for use with LC1D18, LC1D25, LC1D32, and LC1D38 contactors.

  • Adjustable 12–18 A range
  • LC1D contactor compatibility
  • Class 10A trip class
  • Phase-failure trip response
  • 690 V AC / 250 V DC ratings
  • 1 NO + 1 NC auxiliary contacts

Technical Specifications

Product information and specifications for the selected item.

SKU: LRD21

Product Information

BrandSchneider Electric
MPNLRD21
SKULRD21
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum18 A
AC Voltage Rating690 V AC
DC Voltage Rating250 V DC

Electrical Ratings

Current - Maximum18 A
AC Voltage Rating690 V AC
DC Voltage Rating250 V DC
Tripping threshold1.14 +/- 0.06 Ir, conforming to IEC 60947-4-1
Optional high-fault short-circuit rating65 at 480 V, optional high-fault rating with thermal-magnetic circuit-breaker protection kA RMS
Power-circuit terminal connectionsScrew-clamp terminals; 1 cable: flexible 1.5–10 mm² without cable end, flexible 1–4 mm² with cable end, or solid 1–6 mm²
Network typeAC and DC
Product certificationsIEC; UL; CSA; CCC; EAC; BV; RINA; DNV-GL; LROS; ATEX INERIS; UKCA
Rated impulse withstand voltage6 kV
Phase-failure trip responseTrips at 130% of Ir on two phases, with the last phase at 0
Applicable standardsEN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4; GB/T 14048.5; EN 50495
Terminal tightening torqueControl circuit: 1.7; power circuit: 2.5 N·m
Control-circuit terminal connectionsScrew-clamp terminals; 2 cables, 1–2.5 mm² flexible with or without cable end, or solid
Auxiliary contact composition1 NO + 1 NC
Network frequency0...400 Hz

Fuse Type & Indication

Visual IndicationIndicating
Relay applicationMotor protection
Control buttonsRed push-button stop; blue push-button reset
Compatible contactorsLC1D32, LC1D18, LC1D25, LC1D38
Construction and reset modesOpen type; manual and automatic reset

Dimensions & Weight

Height (in.)2.6
Width (in.)1.77
Length (in.)2.76
Weight (lb.)0.273
Mechanical robustnessVibrations: 6 Gn (IEC 60068-2-6); shocks: 15 Gn for 11 ms (IEC 60068-2-7)
Mounting supportUnder contactor; plate or rail with specific accessories
Climatic withstandIACS E10
Restricted-substance complianceEU RoHS compliant; REACh: free of SVHC above the threshold
Storage temperature-60…70 °C
Operating ambient temperature-20…60 without derating, per IEC 60947-4-1 °C
Flame retardanceV1, conforming to UL 94
Ingress protectionIP20, conforming to IEC 60529