Skip to content
Schneider Electric

Schneider Electric TeSys Deca (TeSys D) 3-Pole IEC Contactor, 25A, 220VAC Coil

0 Reviews
SKU
LC1D25M7

The Schneider Electric LC1D25M7 TeSys Deca (TeSys D) IEC contactor has three normally open main poles, a 220 VAC 50/60 Hz coil, and 1 NO plus 1 NC auxiliary contacts. It is rated 25 A for AC-3/AC-3e and 40 A for AC-1 at ≤440 V AC and below 60 °C, with screw-clamp terminals.

  • Three normally open main poles
  • 25 A AC-3 / 40 A AC-1
  • 220 VAC 50/60 Hz coil
  • 1 NO + 1 NC auxiliary contacts
  • Screw-clamp terminals
  • Plate or rail mounting

The Schneider Electric LC1D25M7 TeSys Deca (TeSys D) IEC contactor has three normally open main poles, a 220 VAC 50/60 Hz coil, and 1 NO plus 1 NC auxiliary contacts. It is rated 25 A for AC-3/AC-3e and 40 A for AC-1 at ≤440 V AC and below 60 °C, with screw-clamp terminals.

Product Overview

The Schneider Electric LC1D25M7 TeSys Deca (TeSys D) IEC contactor has three normally open main poles, a 220 VAC 50/60 Hz coil, and 1 NO plus 1 NC auxiliary contacts. It is rated 25 A for AC-3/AC-3e and 40 A for AC-1 at ≤440 V AC and below 60 °C, with screw-clamp terminals.

  • Three normally open main poles
  • 25 A AC-3 / 40 A AC-1
  • 220 VAC 50/60 Hz coil
  • 1 NO + 1 NC auxiliary contacts
  • Screw-clamp terminals
  • Plate or rail mounting

Technical Specifications

Product information and specifications for the selected item.

SKU: LC1D25M7

Product Information

BrandSchneider Electric
MPNLC1D25M7
SKULC1D25M7
UPC / GTIN3389110349764
CategoryLighting Contactors

Key Specs

Number of Poles3
Coil Voltage220 VAC
Contact TypeN.O.
Height (in.)3.35

Switching & Electrical

Number of Poles3
Coil Voltage220 VAC
Contact TypeN.O.
Durability and switching performanceMechanical durability: 15 Mcycles; electrical durability: 1.65 Mcycles at 25 A AC-3/AC-3e and 1.4 Mcycles at 40 A AC-1 (≤440 V); closing time 12–22 ms, opening time 4–19 ms; maximum 3,600 cycles/h at 60 °C.
Hermetic compressor ratingsThree-phase hermetic refrigeration compressor: FLA 25 A; LRA 150 A at 240 V, 125 A at 480 V, and 100 A at 600 V.
Signalling circuit limitsSignalling circuit: 25–400 Hz; minimum switching voltage 17 V, minimum switching current 5 mA, insulation resistance >10 MΩ.
Coil control characteristicsNo built-in suppressor module; drop-out at 0.3–0.6 Uc (-40 to 70 °C); operation at 0.8–1.1 Uc at 50 Hz and 0.85–1.1 Uc at 60 Hz (-40 to 60 °C), or 1–1.1 Uc at 60 to 70 °C.
Protection and environmental durabilityIP20 front face (IEC 60529); TH protective treatment (IEC 60068-2-30); damp-heat withstand per IACS E10 and IEC 60947-1 Annex Q category D; 850 °C fire resistance (IEC 60695-2-1); V1 flame retardance (UL 94).
Auxiliary contactsAuxiliary contacts: 1 NO + 1 NC, mechanically linked; 1 NC mirror contact.
Product certificationsCertifications: UL, CCC, CSA, Marine, UKCA, EAC and CB Scheme.
Insulation and impulse ratingsPower circuit: 690 V IEC, 600 V CSA/UL; signalling circuit: 690 V IEC, 600 V CSA/UL; 6 kV rated impulse withstand (IEC 60947).
Terminal tightening torqueControl circuit: 1.7 N·m; power circuit: 2.5 N·m.
Application and utilization categoriesMotor control and resistive-load applications; AC-1, AC-3, AC-3e and AC-4 utilization categories.
Rated operational voltagePower circuit: up to 690 V AC at 25–400 Hz, or up to 300 V DC.
REACH SVHC statusNo SVHC above the 0.1% threshold at part level.
Making and breaking capacityMaking and breaking capacity: 450 A at 440 V for the power circuit (IEC 60947).
Inrush and hold-in powerInrush: 70 VA at 50/60 Hz; hold-in: 7 VA at 50 Hz and 7.5 VA at 60 Hz (at 20 °C).
Short-time withstand currentPower circuit at 40 °C: 240 A for 10 s, 380 A for 1 s, 50 A for 10 min, and 120 A for 1 min.
Motor horsepower ratings1-phase: 3 hp at 230/240 V and 2 hp at 115 V; 3-phase: 7.5 hp at 200/208 V and 230/240 V, 15 hp at 460/480 V, and 20 hp at 575/600 V (50/60 Hz).
UL/CSA lighting ratingsBallast: 40 A at 600 V; tungsten: 40 A at 480Y/277 V.
Terminal conductor capacityScrew-clamp terminals; control circuit: 1–4 mm² flexible without cable end; power circuit: 2.5–10 mm² flexible without cable end.
Rated operational current by category25 A AC-3 and AC-3e; 40 A AC-1, at ≤440 V AC and below 60 °C.
RoHS statusRoHS (10 substances) compliant without the use of exemptions.
Associated fuse ratingsPower circuit: 63 A gG for coordination type 1 and 40 A gG for type 2 at ≤690 V; signalling circuit: 10 A gG.
Operating conditionsAmbient temperature: -40 to 60 °C; 60 to 70 °C with derating. Operating altitude: 0 to 3000 m.

Dimensions & Weight

Height (in.)3.35
Width (in.)1.77
Length (in.)3.62
Weight (lb.)0.82
Mounting supportMounts on plate or rail.
Construction typeOpen-type construction.

Product Documents

Your cart

1 product 1 unit