The Schneider Electric LC1D25M7 TeSys Deca (TeSys D) IEC contactor has three normally open main poles, a 220 VAC 50/60 Hz coil, and 1 NO plus 1 NC auxiliary contacts. It is rated 25 A for AC-3/AC-3e and 40 A for AC-1 at ≤440 V AC and below 60 °C, with screw-clamp terminals.
The Schneider Electric LC1D25M7 TeSys Deca (TeSys D) IEC contactor has three normally open main poles, a 220 VAC 50/60 Hz coil, and 1 NO plus 1 NC auxiliary contacts. It is rated 25 A for AC-3/AC-3e and 40 A for AC-1 at ≤440 V AC and below 60 °C, with screw-clamp terminals.
The Schneider Electric LC1D25M7 TeSys Deca (TeSys D) IEC contactor has three normally open main poles, a 220 VAC 50/60 Hz coil, and 1 NO plus 1 NC auxiliary contacts. It is rated 25 A for AC-3/AC-3e and 40 A for AC-1 at ≤440 V AC and below 60 °C, with screw-clamp terminals.
Product information and specifications for the selected item.
| Brand | Schneider Electric |
|---|---|
| MPN | LC1D25M7 |
| SKU | LC1D25M7 |
| UPC / GTIN | 3389110349764 |
| Category | Lighting Contactors |
| Number of Poles | 3 |
|---|---|
| Coil Voltage | 220 VAC |
| Contact Type | N.O. |
| Height (in.) | 3.35 |
| Number of Poles | 3 |
|---|---|
| Coil Voltage | 220 VAC |
| Contact Type | N.O. |
| Durability and switching performance | Mechanical durability: 15 Mcycles; electrical durability: 1.65 Mcycles at 25 A AC-3/AC-3e and 1.4 Mcycles at 40 A AC-1 (≤440 V); closing time 12–22 ms, opening time 4–19 ms; maximum 3,600 cycles/h at 60 °C. |
| Hermetic compressor ratings | Three-phase hermetic refrigeration compressor: FLA 25 A; LRA 150 A at 240 V, 125 A at 480 V, and 100 A at 600 V. |
| Signalling circuit limits | Signalling circuit: 25–400 Hz; minimum switching voltage 17 V, minimum switching current 5 mA, insulation resistance >10 MΩ. |
| Coil control characteristics | No built-in suppressor module; drop-out at 0.3–0.6 Uc (-40 to 70 °C); operation at 0.8–1.1 Uc at 50 Hz and 0.85–1.1 Uc at 60 Hz (-40 to 60 °C), or 1–1.1 Uc at 60 to 70 °C. |
| Protection and environmental durability | IP20 front face (IEC 60529); TH protective treatment (IEC 60068-2-30); damp-heat withstand per IACS E10 and IEC 60947-1 Annex Q category D; 850 °C fire resistance (IEC 60695-2-1); V1 flame retardance (UL 94). |
| Auxiliary contacts | Auxiliary contacts: 1 NO + 1 NC, mechanically linked; 1 NC mirror contact. |
| Product certifications | Certifications: UL, CCC, CSA, Marine, UKCA, EAC and CB Scheme. |
| Insulation and impulse ratings | Power circuit: 690 V IEC, 600 V CSA/UL; signalling circuit: 690 V IEC, 600 V CSA/UL; 6 kV rated impulse withstand (IEC 60947). |
| Terminal tightening torque | Control circuit: 1.7 N·m; power circuit: 2.5 N·m. |
| Application and utilization categories | Motor control and resistive-load applications; AC-1, AC-3, AC-3e and AC-4 utilization categories. |
| Rated operational voltage | Power circuit: up to 690 V AC at 25–400 Hz, or up to 300 V DC. |
| REACH SVHC status | No SVHC above the 0.1% threshold at part level. |
| Making and breaking capacity | Making and breaking capacity: 450 A at 440 V for the power circuit (IEC 60947). |
| Inrush and hold-in power | Inrush: 70 VA at 50/60 Hz; hold-in: 7 VA at 50 Hz and 7.5 VA at 60 Hz (at 20 °C). |
| Short-time withstand current | Power circuit at 40 °C: 240 A for 10 s, 380 A for 1 s, 50 A for 10 min, and 120 A for 1 min. |
| Motor horsepower ratings | 1-phase: 3 hp at 230/240 V and 2 hp at 115 V; 3-phase: 7.5 hp at 200/208 V and 230/240 V, 15 hp at 460/480 V, and 20 hp at 575/600 V (50/60 Hz). |
| UL/CSA lighting ratings | Ballast: 40 A at 600 V; tungsten: 40 A at 480Y/277 V. |
| Terminal conductor capacity | Screw-clamp terminals; control circuit: 1–4 mm² flexible without cable end; power circuit: 2.5–10 mm² flexible without cable end. |
| Rated operational current by category | 25 A AC-3 and AC-3e; 40 A AC-1, at ≤440 V AC and below 60 °C. |
| RoHS status | RoHS (10 substances) compliant without the use of exemptions. |
| Associated fuse ratings | Power circuit: 63 A gG for coordination type 1 and 40 A gG for type 2 at ≤690 V; signalling circuit: 10 A gG. |
| Operating conditions | Ambient temperature: -40 to 60 °C; 60 to 70 °C with derating. Operating altitude: 0 to 3000 m. |
| Height (in.) | 3.35 |
|---|---|
| Width (in.) | 1.77 |
| Length (in.) | 3.62 |
| Weight (lb.) | 0.82 |
| Mounting support | Mounts on plate or rail. |