{"product_id":"siemens-3va41-seab-125a-3-phase-main-subfeed-strap-kit-for-revised-p1-panelboards","title":"Siemens 3VA41-SEAB 125A 3-Phase Main\/Subfeed Strap Kit for Revised P1 Panelboards","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eThe Siemens 3VA41-SEAB is a 125 A maximum strap-and-barrier kit for 3-phase, 3-pole main or subfeed applications in Revised P1 panelboards. It is compatible with BL, BQD, xGB, and 3VA4 breakers; a neutral lug assembly and an adapter for BL\/BQD applications are included, but the breaker is not. On 400 A P1 panels, the kit is subfeed-only.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e125 A Maximum\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe kit has a maximum amperage of 125 A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eRevised P1 Compatibility\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThis kit is for Revised P1 panelboards, not original P1 panels.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eBL\/BQD\/xGB\/3VA4 Compatibility\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eCompatible with BL, BQD, xGB, and 3VA4 breakers for main or subfeed applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eBreaker Not Included\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe circuit breaker is not included with the kit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eNeutral Lug Assembly Included\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe neutral lug assembly is included and required for 3-phase, 4-wire systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e400 A P1 Panels: Subfeed Only\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eOn 400 A P1 panels, this kit is specified for subfeed applications only.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMaximum Amperage (A)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eMain-breaker feeds in Revised P1 panelboards\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eSubfeed breaker feeds in Revised P1 panelboards\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eReplacement of previous BL\/BQD\/xGB strap kits in Revised P1 panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Electrical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eNeutral lug requirement\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eNeutral lug assembly required for 3-phase 4-wire systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eSystem wiring\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e3-phase, 3- or 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePhase application\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e3-phase applications only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePole configuration\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e3-pole only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Compatibility\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCompatible main-breaker types\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eBL, BQD, 3VA41, and xGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePanelboard generation compatibility\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eFor Revised P1 panels; not for original P1 panels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCompatible panelboard series\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eRevised P1 panelboards only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eReplacement compatibility\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eReplaces all previous BL\/BQD\/xGB strap kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eRevised P1 400A panel application\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSubfeed only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eBreaker compatibility and use\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eBL\/BQD\/xGB\/3VA4 main or subfeed applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eIncluded adapter\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eAdapter included for BL\/BQD applications\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Installation\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStrap-to-bus connection torque\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e72 lb-in\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":68657039147119,"sku":"3VA41-SEAB","price":597.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-3va41-seab-42426605.jpg?v=1795651898","url":"https:\/\/excelele.com\/products\/siemens-3va41-seab-125a-3-phase-main-subfeed-strap-kit-for-revised-p1-panelboards","provider":"Excel Lighting \u0026 Electrical Supply, Co.","version":"1.0","type":"link"}