The Siemens 3VA6115 is a 150 A, three-pole 3VA61 molded-case circuit breaker with an ETU350 LSI electronic trip unit and M-class breaking capacity. Its interrupting ratings are 35 kAIC at 480 V and 18 kAIC at 600 V, and it is supplied without lugs.

  • 150 A, three-pole rating
  • ETU350 LSI electronic trip
  • Interrupting ratings at 480/600 V
  • M-class breaking capacity
  • Supplied without lugs
  • Bolt-on mounting

The Siemens 3VA6115 is a 150 A, three-pole 3VA61 molded-case circuit breaker with an ETU350 LSI electronic trip unit and M-class breaking capacity. Its interrupting ratings are 35 kAIC at 480 V and 18 kAIC at 600 V, and it is supplied without lugs.

Product Overview

The Siemens 3VA6115 is a 150 A, three-pole 3VA61 molded-case circuit breaker with an ETU350 LSI electronic trip unit and M-class breaking capacity. Its interrupting ratings are 35 kAIC at 480 V and 18 kAIC at 600 V, and it is supplied without lugs.

  • 150 A, three-pole rating
  • ETU350 LSI electronic trip
  • Interrupting ratings at 480/600 V
  • M-class breaking capacity
  • Supplied without lugs
  • Bolt-on mounting

Technical Specifications

Product information and specifications for the selected item.

SKU: 3VA6115

Product Information

BrandSiemens
MPN3VA6115
SKU3VA6115
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)150
Voltage600 V
Interruption TypeStandard Trip
Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)150
Voltage600 V
Interruption TypeStandard Trip
Electrical endurance at AC-1, 380/415 V9,000 cycles
Power loss at rated current, hot AC operation29 W per device
Ground-fault protectionNo
Electrical lifetime at 600 V9,000 cycles
Short-circuit pickup adjustment range (ISD)1.5–10 × IR
100%-rated operationNo
Storage temperature range-40 to 80 °C
Instantaneous pickup (Ii)1,500 A
Overload pickup adjustment range (IR)60–150 A
Operating ambient temperature range-25 to 70 °C
Instantaneous trip setting (II)10 Ă— IN
Mechanical service life20,000 typical switching cycles
Electrical endurance at AC-1, 690 V5,000 cycles
Long-time delay setting (tld)0.5–17 s
Electrical lifetime at 480 V9,000 cycles
Long-time pickup adjustment (Ir)60–150 A
Short-time pickup adjustment (Isd/Ir)1.5–10 × Ir

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral
Series Type3VA61
Trip-setting interfaceDial-adjustable
Lug configurationWithout lugs
Front protection ratingIP40
Reverse-feed compatibilitySuitable for reverse-feed applications
Trip-unit interchangeabilityNon-interchangeable

Pack & Smart Features

Bundle/SingleSingle Product
Communication functionNo
Other measurement functionNo

Certifications

Certifications and ListingsROHS, UL Listed

Dimensions & Weight

Height (in.)7.8
Width (in.)4.13
Length (in.)4.21
Weight (lb.)4.57