Skip to content

Siemens BF240A 40A 2P 120/240VAC Class A GFCI Bolt-On Circuit Breaker

0 Reviews
SKU
BF240A

The Siemens BF240A is a bolt-on, two-pole 40 A circuit breaker rated for 120/240 V AC, with Class A (5 mA) GFCI personnel protection and a pigtail neutral connection.

  • 40 A, 2-Pole Rating
  • 120/240 V AC Rating
  • Class A 5 mA GFCI
  • 10 kA Interrupting Rating
  • Bolt-On Mounting
  • Pigtail Neutral

The Siemens BF240A is a bolt-on, two-pole 40 A circuit breaker rated for 120/240 V AC, with Class A (5 mA) GFCI personnel protection and a pigtail neutral connection.

Product Overview

The Siemens BF240A is a bolt-on, two-pole 40 A circuit breaker rated for 120/240 V AC, with Class A (5 mA) GFCI personnel protection and a pigtail neutral connection.

  • 40 A, 2-Pole Rating
  • 120/240 V AC Rating
  • Class A 5 mA GFCI
  • 10 kA Interrupting Rating
  • Bolt-On Mounting
  • Pigtail Neutral

Technical Specifications

Product information and specifications for the selected item.

SKU: BF240A

Product Information

BrandSiemens
MPNBF240A
SKUBF240A
UPC / GTIN887621215439
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)40
Voltage120/240 V AC
Interruption TypeGFCI
Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypePigtail

Electrical Ratings

Maximum Amperage (A)40
Voltage120/240 V AC
Interruption TypeGFCI
Interrupting rating10,000 A
Additional application ratingsHACR and SWD rated
Ground-fault disconnect behaviorDe-energizes all ungrounded conductors of the circuit
Ground-Fault Trip ActionDe-energizes all ungrounded conductors of the circuit.
Supported system configuration208Y/120 V, 3-phase, 4-wire systems
Compatible System ConfigurationCan be installed on 208Y/120 V, 3-phase, 4-wire systems.
Ground-Fault Trip ThresholdCurrent imbalance of 4–6 mA or more between load conductors causes the ground-fault sensor to trip.
GFCI protectionClass A (5 mA) personnel protection
Ground-fault trip imbalance between load conductors4–6 or more mA

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypePigtail
Series TypeBLF
Load-neutral requirementNot required on the circuit
RF Interference ShieldingShielding prevents RF interference to resist false tripping.
RF interference resistanceShielded to prevent RF interference; resists false tripping

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item
Self-test operationAutomatically and continuously self-tests; trips itself if compromised

Certifications

Certifications and ListingsCSA Certified, cUL Listed, UL Listed

Dimensions & Weight

Height (in.)2.78
Width (in.)2
Length (in.)3
Weight (lb.)0.992

Product Documents

Your cart

1 product 1 unit