Siemens BLF Series B230GF 30A 2-Pole 120/240VAC 10kA Class A Bolt-On GFCI Circuit Breaker

0 Reviews
SKU
B230GF

The Siemens B230GF is a BLF Series, 30 A, 2-pole GFCI circuit breaker rated for 120/240 V AC, with a 10 kA interrupt rating and Class A 5 mA ground-fault protection. It uses bolt-on mounting and a pigtail neutral, is HACR and SWD rated, and is UL Listed and cUL Listed; a load neutral is not required on the protected circuit.

  • 30 A, 2-Pole Configuration
  • 120/240 V AC Rating
  • Class A, 5 mA GFCI Protection
  • 10 kA Interrupt Rating
  • Bolt-On with Pigtail Neutral
  • UL and cUL Listed

The Siemens B230GF is a BLF Series, 30 A, 2-pole GFCI circuit breaker rated for 120/240 V AC, with a 10 kA interrupt rating and Class A 5 mA ground-fault protection. It uses bolt-on mounting and a pigtail neutral, is HACR and SWD rated, and is UL Listed and cUL Listed; a load neutral is not required on the protected circuit.

Product Overview

The Siemens B230GF is a BLF Series, 30 A, 2-pole GFCI circuit breaker rated for 120/240 V AC, with a 10 kA interrupt rating and Class A 5 mA ground-fault protection. It uses bolt-on mounting and a pigtail neutral, is HACR and SWD rated, and is UL Listed and cUL Listed; a load neutral is not required on the protected circuit.

  • 30 A, 2-Pole Configuration
  • 120/240 V AC Rating
  • Class A, 5 mA GFCI Protection
  • 10 kA Interrupt Rating
  • Bolt-On with Pigtail Neutral
  • UL and cUL Listed

Technical Specifications

Product information and specifications for the selected item.

SKU: B230GF

Product Information

BrandSiemens
MPNB230GF
SKUB230GF
UPC / GTIN195125299627
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)30
Voltage120/240 V AC
Interruption TypeGFCI
Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypePigtail

Electrical Ratings

Maximum Amperage (A)30
Voltage120/240 V AC
Interruption TypeGFCI
Ground-fault trip sensitivityClass A (5 mA); sensor trips on a 4–6 mA or greater imbalance between load conductors
Ungrounded conductor disconnectionDe-energizes all ungrounded conductors in the circuit
Additional ratingsHACR and SWD rated
Ground-fault disconnect actionDe-energizes all ungrounded conductors of the circuit.
Ground-fault trip thresholdGround-fault sensor trips on a 4–6 mA or greater current imbalance between load conductors.

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypePigtail
Series TypeBLF
Load-neutral requirementA load neutral is not required on the protected circuit

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item
Self-test behaviorAutomatically and continuously self-tests; trips itself if compromised
RF interference shieldingShielded to prevent RF interference and resist false tripping

Certifications

Certifications and ListingscUL Listed, UL Listed

Dimensions & Weight

Height (in.)2.78
Width (in.)2
Length (in.)2.999
Weight (lb.)0.8