Skip to content

Siemens BQD240 2P 40A Molded-Case Circuit Breaker, 480Y/277VAC

0 Reviews
SKU
BQD240

The Siemens BQD240 is a two-pole, 40 A molded-case circuit breaker with 480Y/277 V AC and 125/250 V DC ratings, bolt-on mounting, and a fixed T-M trip. Its interrupting ratings are 14 kAIC at 480/277 V AC and 65 kAIC at 240 V AC.

  • 2-Pole Configuration
  • 40 A Current Rating
  • AC and DC Voltage Ratings
  • Interrupting Capacity
  • Fixed T-M Trip
  • Bolt-On Mounting

The Siemens BQD240 is a two-pole, 40 A molded-case circuit breaker with 480Y/277 V AC and 125/250 V DC ratings, bolt-on mounting, and a fixed T-M trip. Its interrupting ratings are 14 kAIC at 480/277 V AC and 65 kAIC at 240 V AC.

Product Overview

The Siemens BQD240 is a two-pole, 40 A molded-case circuit breaker with 480Y/277 V AC and 125/250 V DC ratings, bolt-on mounting, and a fixed T-M trip. Its interrupting ratings are 14 kAIC at 480/277 V AC and 65 kAIC at 240 V AC.

  • 2-Pole Configuration
  • 40 A Current Rating
  • AC and DC Voltage Ratings
  • Interrupting Capacity
  • Fixed T-M Trip
  • Bolt-On Mounting

Technical Specifications

Product information and specifications for the selected item.

SKU: BQD240

Product Information

BrandSiemens
MPNBQD240
SKUBQD240
UPC / GTIN783643277267
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)40
Voltage480Y/277 V AC
Interruption TypeStandard Trip
Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)40
Voltage480Y/277 V AC
Interruption TypeStandard Trip
Current-rating reference temperature40 °C
AC frequency50/60 Hz
Frame rating100 A
Rated supply frequency50/60 Hz
HID lighting ratingHID rated
Maximum operating ambient temperature40 °C
System compatibility limitationNot suitable for 3 phase delta 480V AC grounded “B” phase applications
System application limitationNot suitable for 3-phase delta systems with grounded B phase
HID application ratingHID rated
HACR ratingHACR rated
Circuit-breaker frame size100 A

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral
Series TypeBQD
Reverse-feed suitabilitySuitable for reverse-feed applications
Terminal wire temperature class60/75 °C
Lug connection locationLoad end only
Load-terminal conductor rangeCopper: #14–#6; aluminum: #12–#6 AWG
Electrical connection styleLow tab
Load-end lug conductor rangesCu #14–#6 AWG; Al #12–#6 AWG
Terminal locationLoad end only
Compatible lug wire temperature rating60/75 °C

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsCSA Certified, UL Listed

Dimensions & Weight

Height (in.)2
Width (in.)3
Length (in.)4
Weight (lb.)1.1

Product Documents