The Siemens BQD360 is a 3-pole, 60 A molded-case circuit breaker rated 480Y/277 V AC, with bolt-on panelboard mounting and a 100 A frame. It has a standard thermal-magnetic trip, is HACR rated, UL Listed and CSA Certified, and has interrupting ratings of 14 kAIC at 480/277 V AC and 65 kA UL RMS symmetrical at 240 V AC.

  • 3-Pole, 60 A Rating
  • 480Y/277 V AC Rating
  • Interrupting Ratings by Voltage
  • Bolt-On Panelboard Mount
  • Standard Thermal-Magnetic Trip
  • Copper and Aluminum Terminal Ranges

The Siemens BQD360 is a 3-pole, 60 A molded-case circuit breaker rated 480Y/277 V AC, with bolt-on panelboard mounting and a 100 A frame. It has a standard thermal-magnetic trip, is HACR rated, UL Listed and CSA Certified, and has interrupting ratings of 14 kAIC at 480/277 V AC and 65 kA UL RMS symmetrical at 240 V AC.

Product Overview

The Siemens BQD360 is a 3-pole, 60 A molded-case circuit breaker rated 480Y/277 V AC, with bolt-on panelboard mounting and a 100 A frame. It has a standard thermal-magnetic trip, is HACR rated, UL Listed and CSA Certified, and has interrupting ratings of 14 kAIC at 480/277 V AC and 65 kA UL RMS symmetrical at 240 V AC.

  • 3-Pole, 60 A Rating
  • 480Y/277 V AC Rating
  • Interrupting Ratings by Voltage
  • Bolt-On Panelboard Mount
  • Standard Thermal-Magnetic Trip
  • Copper and Aluminum Terminal Ranges

Technical Specifications

Product information and specifications for the selected item.

SKU: BQD360

Product Information

BrandSiemens
MPNBQD360
SKUBQD360
UPC / GTIN783643277427
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)60
Voltage480Y/277 V AC
Interruption TypeStandard Trip
Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)60
Voltage480Y/277 V AC
Interruption TypeStandard Trip
UL RMS symmetrical interrupting rating at 240 V AC65 kA
Maximum operating ambient temperature40 °C
Frame size100 A
Three-phase delta 480 V applicationNot suitable
Rated frequency50/60 Hz
Delta system compatibilityNot suitable for 3 phase delta 480V AC grounded “B” phase applications

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral
Series TypeBQD
Copper conductor size range#8–#1 AWG
Lug connection sideLoad end only
Reverse-feed suitabilitySuitable
Wire temperature rating60/75 °C
Compatible conductor temperature rating60/75 °C
Reverse-feed useSuitable
Electrical connection styleLow tab
Overload release designThermal magnetic trip unit
Aluminum conductor size range#6–#1/0 AWG
Lug termination endLoad end only

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsCSA Certified, UL Listed
HACR ratingHACR rated

Dimensions & Weight

Height (in.)4.49
Width (in.)3
Length (in.)2.7
Weight (lb.)1.94