The Siemens BQD360 is a 3-pole, 60 A molded-case circuit breaker rated 480Y/277 V AC, with bolt-on panelboard mounting and a 100 A frame. It has a standard thermal-magnetic trip, is HACR rated, UL Listed and CSA Certified, and has interrupting ratings of 14 kAIC at 480/277 V AC and 65 kA UL RMS symmetrical at 240 V AC.
3-Pole, 60 A Rating
480Y/277 V AC Rating
Interrupting Ratings by Voltage
Bolt-On Panelboard Mount
Standard Thermal-Magnetic Trip
Copper and Aluminum Terminal Ranges
The Siemens BQD360 is a 3-pole, 60 A molded-case circuit breaker rated 480Y/277 V AC, with bolt-on panelboard mounting and a 100 A frame. It has a standard thermal-magnetic trip, is HACR rated, UL Listed and CSA Certified, and has interrupting ratings of 14 kAIC at 480/277 V AC and 65 kA UL RMS symmetrical at 240 V AC.
The Siemens BQD360 is a 3-pole, 60 A molded-case circuit breaker rated 480Y/277 V AC, with bolt-on panelboard mounting and a 100 A frame. It has a standard thermal-magnetic trip, is HACR rated, UL Listed and CSA Certified, and has interrupting ratings of 14 kAIC at 480/277 V AC and 65 kA UL RMS symmetrical at 240 V AC.
3-Pole, 60 A Rating
480Y/277 V AC Rating
Interrupting Ratings by Voltage
Bolt-On Panelboard Mount
Standard Thermal-Magnetic Trip
Copper and Aluminum Terminal Ranges
Technical Specifications
Product information and specifications for the selected item.
SKU: BQD360
Product Information
Brand
Siemens
MPN
BQD360
SKU
BQD360
UPC / GTIN
783643277427
Category
Circuit Breakers
Key Specs
Maximum Amperage (A)
60
Voltage
480Y/277 V AC
Interruption Type
Standard Trip
Breaker Type
Standard
Mounting Type
Bolt-On
Neutral Connection Type
Non-Neutral
Electrical Ratings
Maximum Amperage (A)
60
Voltage
480Y/277 V AC
Interruption Type
Standard Trip
UL RMS symmetrical interrupting rating at 240 V AC
65 kA
Maximum operating ambient temperature
40 °C
Frame size
100 A
Three-phase delta 480 V application
Not suitable
Rated frequency
50/60 Hz
Delta system compatibility
Not suitable for 3 phase delta 480V AC grounded “B” phase applications
Breaker Configuration
Breaker Type
Standard
Mounting Type
Bolt-On
Neutral Connection Type
Non-Neutral
Series Type
BQD
Copper conductor size range
#8–#1 AWG
Lug connection side
Load end only
Reverse-feed suitability
Suitable
Wire temperature rating
60/75 °C
Compatible conductor temperature rating
60/75 °C
Reverse-feed use
Suitable
Electrical connection style
Low tab
Overload release design
Thermal magnetic trip unit
Aluminum conductor size range
#6–#1/0 AWG
Lug termination end
Load end only
Pack & Smart Features
Bundle/Single
Single Product
Pack Options
Single Item
Certifications
Certifications and Listings
CSA Certified, UL Listed
HACR rating
HACR rated
Dimensions & Weight
Height (in.)
4.49
Width (in.)
3
Length (in.)
2.7
Weight (lb.)
1.94
Product Documents
Siemens Molded Case Circuit Breakers — General Application Catalog, BQD/CQD Product Guide
Other
Open / download file
Siemens SPEEDFAX™ Product Catalog, Section 7: Molded Case Circuit Breakers
Other
Open / download file