The Siemens eQP QF120DFN is a 20 A, single-pole, 120 V AC dual-function circuit breaker combining CAFCI and Class A 5 mA GFCI protection. Its plug-on-neutral connection is specified for plug-on-neutral load centers, and it has a 10 kA interrupting rating.
The Siemens eQP QF120DFN is a 20 A, single-pole, 120 V AC dual-function circuit breaker combining CAFCI and Class A 5 mA GFCI protection. Its plug-on-neutral connection is specified for plug-on-neutral load centers, and it has a 10 kA interrupting rating.
The Siemens eQP QF120DFN is a 20 A, single-pole, 120 V AC dual-function circuit breaker combining CAFCI and Class A 5 mA GFCI protection. Its plug-on-neutral connection is specified for plug-on-neutral load centers, and it has a 10 kA interrupting rating.
Product information and specifications for the selected item.
| Brand | Siemens |
|---|---|
| MPN | QF120DFN |
| SKU | QF120DFN |
| Category | Circuit Breakers |
| Maximum Amperage (A) | 20 |
|---|---|
| Voltage | 120 V |
| Interruption Type | AFCI/GFCI |
| Breaker Type | Miniature |
| Mounting Type | Plug-On |
| Neutral Connection Type | Neutral |
| Maximum Amperage (A) | 20 |
|---|---|
| Voltage | 120 V |
| Interruption Type | AFCI/GFCI |
| Application ratings | HACR and SWD rated |
| GFCI protection class | Class A (5 mA) |
| AFCI arc-fault detection coverage | Line-to-ground, line-to-neutral, and series arcs |
| Interrupting rating (AIC) | 10 kAIC |
| Ground-fault protection class and threshold | Class A (5 mA); intended for personnel protection |
| Interrupting capacity | 10,000 AIC |
| Breaker Type | Miniature |
|---|---|
| Mounting Type | Plug-On |
| Neutral Connection Type | Neutral |
| Series Type | eQP |
| Terminal torque | 25 lb-in |
| Conductor range | Copper: #14–#8 AWG; aluminum: #12–#8 AWG |
| Lug orientation | Both lugs are at the same angle |
| Terminal wire range — copper | #14–#8 AWG Cu |
| Conductor connection feature | Insta-Wire connectors |
| Compatible load center type | Plug-on-neutral load centers |
| Connector feature | Insta-Wire connectors |
| Terminal wire range — aluminum | #12–#8 AWG Al |
| Neutral terminal installation | The plug-on neutral terminal must connect to the panel neutral |
| Bundle/Single | Single Product |
|---|---|
| Pack Options | Single Item |
| Troubleshooting indication | LED indicators for troubleshooting |
| Self-test failure response | Trips and blinks lights if protection is compromised |
| Self-test operation | Automatically and continuously self-tests for device malfunction |
| Certifications and Listings | UL Listed |
|---|---|
| Thermoset share (EPD composition) | 37.45 % |
| Thermoplastic share (EPD composition) | 13.23 % |
| Carbon steel share (EPD composition) | 17.38 % |
| EPD energy recoverability potential | Up to 49 % |
| EPD recyclability potential | Up to 37 % |
| Copper and alloys share (EPD composition) | 10.5 % |