Skip to content

Siemens I-T-E Vacu-Break Type BD Fusible Busway Switch Plug, 200A, 600VAC, 3P, 3-wire

0 Reviews
SKU
BOS14354

The Siemens I-T-E Vacu-Break Type BD is a fusible safety-switch plug for BD plug-in busway, rated 200 A at 600 VAC in a 3-pole, 3-wire configuration. It is floor-operable, provides line-terminal protection, and is UL Listed.

  • 200 A Rating
  • 600 VAC Rating
  • Three-Pole, Three-Wire Configuration
  • BD Plug-In Busway Compatibility
  • Class R, H, or K Fuse Compatibility
  • Single-Conductor Lug Range

The Siemens I-T-E Vacu-Break Type BD is a fusible safety-switch plug for BD plug-in busway, rated 200 A at 600 VAC in a 3-pole, 3-wire configuration. It is floor-operable, provides line-terminal protection, and is UL Listed.

Product Overview

The Siemens I-T-E Vacu-Break Type BD is a fusible safety-switch plug for BD plug-in busway, rated 200 A at 600 VAC in a 3-pole, 3-wire configuration. It is floor-operable, provides line-terminal protection, and is UL Listed.

  • 200 A Rating
  • 600 VAC Rating
  • Three-Pole, Three-Wire Configuration
  • BD Plug-In Busway Compatibility
  • Class R, H, or K Fuse Compatibility
  • Single-Conductor Lug Range

Technical Specifications

Product information and specifications for the selected item.

SKU: BOS14354

Product Information

BrandSiemens
MPNBOS14354
SKUBOS14354
UPC / GTIN783643700420
CategoryDisconnects & Safety Switches

Key Specs

Maximum Amperage (A)200
Phase Type3 Phase
Disconnect TypeSafety Switch

Switch Ratings

Maximum Amperage (A)200
Phase Type3 Phase
Maximum time-delay horsepower150 hp
Interrupt rating65 kA at 480 VAC
Switching actionQuick-make/quick-break

Disconnect Configuration

Disconnect TypeSafety Switch
FusedFused
Lug conductor rangeOne conductor, #6 AWG–250 MCM Cu/Al
Busway flange fitFits 4 1/16-in-wide busway sections; pipe spacers are required for larger sections
Required plug-in openings1 opening
OrientationHorizontal
Plug-in opening requirementOne plug-in opening (for plugs rated 400 A and smaller)
Mechanical lug size250 MCM
Fuses suppliedNot included
Terminal protectionProvided
Fuse class compatibilityClass R, H, and K
Busway compatibilityFor BD plug-in busway
Operating methodFloor-operable
Busway width and spacer requirementFlanges fit 4 1/16-in-wide busway sections; pipe spacers are required for larger sections
Conduit knockout sizes1, 1¼, 1½, 2, and 2½ in
Fuse supplyNot included; must be purchased separately

Enclosure & Certifications

Certifications and ListingsUL Listed

Dimensions & Weight

Height (in.)12
Width (in.)11
Length (in.)21

Product Documents

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.