Skip to content

Siemens P2/P3 Single-Mount Branch Strap Kit for 3VA52/61/62, 250A Max

0 Reviews
SKU
BBKVA5262P2S

The Siemens BBKVA5262P2S is a bolt-on branch strap kit for Siemens P2 and P3 panelboards used with 3VA52, 3VA61, or 3VA62 breakers up to 250 A. It uses 6 inches of branch unit space and includes parts for single- and three-phase installations, hardware, and deadfront components; the breaker and center strip are not included.

  • P2/P3 Panelboard Compatibility
  • 3VA52/61/62 Breaker Compatibility
  • 250 A Maximum
  • 6-Inch Branch Unit Space
  • Bolt-On Mounting
  • Phase Buses and Deadfront Parts

The Siemens BBKVA5262P2S is a bolt-on branch strap kit for Siemens P2 and P3 panelboards used with 3VA52, 3VA61, or 3VA62 breakers up to 250 A. It uses 6 inches of branch unit space and includes parts for single- and three-phase installations, hardware, and deadfront components; the breaker and center strip are not included.

Product Overview

The Siemens BBKVA5262P2S is a bolt-on branch strap kit for Siemens P2 and P3 panelboards used with 3VA52, 3VA61, or 3VA62 breakers up to 250 A. It uses 6 inches of branch unit space and includes parts for single- and three-phase installations, hardware, and deadfront components; the breaker and center strip are not included.

  • P2/P3 Panelboard Compatibility
  • 3VA52/61/62 Breaker Compatibility
  • 250 A Maximum
  • 6-Inch Branch Unit Space
  • Bolt-On Mounting
  • Phase Buses and Deadfront Parts

Technical Specifications

Product information and specifications for the selected item.

SKU: BBKVA5262P2S

Product Information

BrandSiemens
MPNBBKVA5262P2S
SKUBBKVA5262P2S
UPC / GTIN195125059825
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)250
Mounting TypeBolt-On

Electrical Ratings

Maximum Amperage (A)250
Single-Phase Bus ConfigurationOmit the B-phase connector bus on single-phase systems.
Supported Wiring SystemsConnects to single-phase 2- or 3-wire systems, or three-phase 3- or 4-wire systems.
Compatible system wiring1-phase, 2- or 3-wire; 3-phase, 3- or 4-wire

Breaker Configuration

Mounting TypeBolt-On
Series Type3VA52/61/62
Tightening torque for 5/16-18 Ă— 3/4-in machine screws144 lb-in
OEM ApplicationThe kit's parts may also be used by an OEM for a horizontal main in unit space.
Fastener Torque#8-32 x 9/32-inch screws: 30 lb-in; 1/4-20 screws (listed lengths): 72 lb-in; 5/16-18 x 3/4-inch screws: 144 lb-in.
Deadfront AdjustmentA dual-mounted center strip over the kit area may require deadfront modification; a blank filler is needed if the kit leaves part of a removed module opening uncovered.
Connector Bus Screw LengthUse 5/8-inch screws for single-lamination phase bus and 1-inch screws for double-lamination phase bus.
Orientation AdjustmentThe top barrier can be rotated 180°; the breaker load side may face the right or left gutter.
Compatible panelboardsP2 and P3 panelboards

Pack & Smart Features

Bundle/SingleBundle
Pack OptionsSingle Item
Included ComponentsIncludes A-, B-, and C-phase connector buses, separate P2 and P3 deadfront plates, and an escutcheon plate.
Breaker IncludedThe circuit breaker is not included and must be purchased separately.
Breaker inclusionNot included; must be purchased separately

Certifications

Certifications and ListingsROHS

Dimensions & Weight

Height (in.)19.75
Width (in.)5
Length (in.)10.25
Weight (lb.)0.2
Kit Location IncrementLocate dimension D in 3-inch increments; add 0.25 inch when measuring D from the bus support.
Breaker Connection Hole SpacingKeep the breaker connection holes 1.38 inches apart when aligning the connectors.
Required panelboard unit space6 in
Required Branch Unit SpaceUses 6 inches of branch unit space for one 2-pole or 3-pole breaker.