Skip to content

Siemens Power Mod 5-Position Outdoor Ringless Meter Stack, 125A Max, No Bypass

0 Reviews
SKU
WMM52125RJ

The Siemens WMM52125RJ Power Mod is an outdoor, ringless five-position meter stack with five-jaw sockets, a 125 A maximum tenant-breaker rating, and no bypass. It is rated 240 V AC, with 3-phase, 4-wire incoming and 1-phase, 3-wire outgoing service, in a NEMA 3R galvanized-steel enclosure.

  • Five-Position, Five-Jaw Ringless Stack
  • 125 A Maximum Tenant Breaker
  • 3-Phase In, 1-Phase Out
  • 240 V AC Rating
  • NEMA 3R Galvanized-Steel Enclosure
  • 65,000 Maximum AIC Rating

Product Overview

The Siemens WMM52125RJ Power Mod is an outdoor, ringless five-position meter stack with five-jaw sockets, a 125 A maximum tenant-breaker rating, and no bypass. It is rated 240 V AC, with 3-phase, 4-wire incoming and 1-phase, 3-wire outgoing service, in a NEMA 3R galvanized-steel enclosure.

Technical Specifications

Product information and specifications for the selected item.

SKU: WMM52125RJ

Product Information

BrandSiemens
MPNWMM52125RJ
SKUWMM52125RJ
UPC / GTIN040892147575
CategoryMeter Stacks

Key Specs

Meter Stack Amperage Rating (A)125 A
NEMA Enclosure RatingNEMA 3R
Phase1/3
Voltage Rating240 V AC
Type5-Position

Electrical Ratings

Meter Stack Amperage Rating (A)125 A
Voltage Rating240 V AC
Phase1/3
AIC qualificationDetermined by tenant-breaker AIC; higher ratings may be achieved through approved series-rating combinations.
Phase bus strap tightening torque60-65 lb-in
Delta-system compatibilityApproved for 3-phase, 4-wire delta systems; field-phase away from B (A and C only)
Factory socket phasingAB, BC, AC, AB, BC, top to bottom
Maximum AIC rating65,000 AIC
QuickConnect torque400-440 lb-in
Main bus rating1200 A
Field phasingEach socket can be phased AB, BC, or AC using line bus straps

Stack Configuration

Type5-Position
Connection accessAll connections are front accessible
Neutral lug relocationCan move from below the cross bus to an alternate location above it
Ground lug relocationGround lug assembly can be relocated to the top of the stack
Compatible tenant breaker typesQP, QPH, HQP, MP-T, MP-HT, MP-MT
QuickRoll mounting featureQuickRoll bracket lets the module glide down the mounting rail
QuickBolt strap requirementRetaining strap must be removed before energizing
Fifth-jaw configurationCan be isolated if needed
Fifth-jaw isolationCan be isolated if needed
Mounting hardwareMounting rails and adjustable brackets for secure mounting

Enclosure & Material

NEMA Enclosure RatingNEMA 3R
MaterialGalvanized Steel
Breaker-cover lockingLockable
UL standardsUL 67 and UL 414
Backplate knockout provisionRemovable back plate with six KOs sized 1, 1-1/4, 1-1/2, and 2 in
Rain channelMovable to simplify wiring
Meter-cover lockingAccepts common utility barrel locks
Paint finishANSI 61 paint

Dimensions & Weight

Height (in.)61.31
Width (in.)13.09
Length (in.)8.09
Weight (lb.)92.9
Center-punch mounting locators6