The Siemens QRH23B200 is a three-pole QRH2 molded-case circuit breaker rated 200 A with a 25 kAIC interrupting rating at 240 VAC. It is HACR rated, uses standard-trip operation, has bolt-on mounting and installed aluminum load-side lugs, and is UL listed for reverse-feed applications and CSA certified.
3-Pole, 200A Rating
240 VAC, 25 kAIC
HACR-Rated, Standard-Trip Breaker
Bolt-On Mounting
Aluminum Load-Side Lugs
Reverse-Feed UL Listing
The Siemens QRH23B200 is a three-pole QRH2 molded-case circuit breaker rated 200 A with a 25 kAIC interrupting rating at 240 VAC. It is HACR rated, uses standard-trip operation, has bolt-on mounting and installed aluminum load-side lugs, and is UL listed for reverse-feed applications and CSA certified.
The Siemens QRH23B200 is a three-pole QRH2 molded-case circuit breaker rated 200 A with a 25 kAIC interrupting rating at 240 VAC. It is HACR rated, uses standard-trip operation, has bolt-on mounting and installed aluminum load-side lugs, and is UL listed for reverse-feed applications and CSA certified.
3-Pole, 200A Rating
240 VAC, 25 kAIC
HACR-Rated, Standard-Trip Breaker
Bolt-On Mounting
Aluminum Load-Side Lugs
Reverse-Feed UL Listing
Technical Specifications
Product information and specifications for the selected item.
SKU: QRH23B200
Product Information
Brand
Siemens
MPN
QRH23B200
SKU
QRH23B200
UPC / GTIN
804766136801
Category
Circuit Breakers
Key Specs
Maximum Amperage (A)
200
Voltage
240 V AC
Interruption Type
Standard Trip
Breaker Type
Standard
Mounting Type
Bolt-On
Electrical Ratings
Maximum Amperage (A)
200
Voltage
240 V AC
Interruption Type
Standard Trip
AC frequency
50/60 Hz
Fixed instantaneous trip range
1,500–2,500 A
Ambient calibration and high-temperature operation
Standard calibration at 40°C ambient; derating required at higher temperatures
Ambient calibration and derating
Calibrated at 40; derating required at higher ambient temperatures °C
Breaker Configuration
Breaker Type
Standard
Mounting Type
Bolt-On
Series Type
QRH2
Supported applications
Load centers, panelboards, switchboards, meter centers, modular metering, and OEM control panels
Connection design
Cable-in, cable-out
Manual trip feature
Push-to-trip button
Load-side lugs
Supplied as standard
Terminal screw tightening torque by conductor size
100 for #3–1/0 AWG; 225 for 2/0 AWG–300 kcmil in-lb
Terminal wire-grip screw torque
100 for #3–1/0 AWG; 225 for 2/0 AWG–300 kcmil in-lb
Included lug conductor compatibility
#3–300 kcmil, aluminum or copper conductors
Reverse-feed suitability
Suitable for reverse-feed applications
Lug wire temperature rating
75 °C
Rated conductor temperature for supplied lugs
75 °C
Pack & Smart Features
Bundle/Single
Single Product
Pack Options
Single Item
Certifications
Certifications and Listings
CSA Certified, UL Certified, UL Listed
Dimensions & Weight
Height (in.)
7
Width (in.)
4.5
Length (in.)
2.53
Weight (lb.)
4.5
Product Documents
Molded Case Circuit Breakers — Series Connected Short Circuit Ratings
Other
Open / download file
Circuit Breaker Frame QR — Installation Instructions (I.L. No. 814516A)
Installation manual
Open / download file
Molded Case Circuit Breakers — SPEEDFAX Product Catalog, Section 7 (QR 250A Frame)
Spec sheet
Open / download file