Skip to content

Siemens SENTRON 3VA4 1P 30A Molded-Case Circuit Breaker

0 Reviews
SKU
3VA4130-4ED14-0AA0-USD

The Siemens SENTRON 3VA4 3VA4130-4ED14-0AA0-USD is a single-pole, 30 A molded-case circuit breaker with a 125 A frame and bolt-on mounting. It is rated 480 V AC, with a stated 25 kAIC interrupting rating at 277 V, and uses fixed TM210 thermal-magnetic protection. It is UL Listed.

  • 30 A, Single-Pole Breaker
  • 480 V AC Rating
  • 25 kAIC at 277 V
  • 125 A Frame, Bolt-On Mounting
  • TM210 Thermal-Magnetic Trip
  • UL Listed

The Siemens SENTRON 3VA4 3VA4130-4ED14-0AA0-USD is a single-pole, 30 A molded-case circuit breaker with a 125 A frame and bolt-on mounting. It is rated 480 V AC, with a stated 25 kAIC interrupting rating at 277 V, and uses fixed TM210 thermal-magnetic protection. It is UL Listed.

Product Overview

The Siemens SENTRON 3VA4 3VA4130-4ED14-0AA0-USD is a single-pole, 30 A molded-case circuit breaker with a 125 A frame and bolt-on mounting. It is rated 480 V AC, with a stated 25 kAIC interrupting rating at 277 V, and uses fixed TM210 thermal-magnetic protection. It is UL Listed.

  • 30 A, Single-Pole Breaker
  • 480 V AC Rating
  • 25 kAIC at 277 V
  • 125 A Frame, Bolt-On Mounting
  • TM210 Thermal-Magnetic Trip
  • UL Listed

Technical Specifications

Product information and specifications for the selected item.

SKU: 3VA4130-4ED14-0AA0-USD

Product Information

BrandSiemens
MPN3VA4130-4ED14-0AA0-USD
SKU3VA4130-4ED14-0AA0-USD
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)30
Voltage480 V AC
Interruption TypeStandard Trip
Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)30
Voltage480 V AC
Interruption TypeStandard Trip
Instantaneous short-circuit pickupIi = 10 Ă— In
L-tripping response delay (tr), I2t characteristic1 s minimum and 1 s maximum
Storage temperature range-40 to 80 °C
Overcurrent-release protection functionLI
Mechanical service life15,000 typical operating cycles
Operating ambient temperature range-25 to 70 °C
Operating-current derating by ambient temperature45°C: 29; 50°C: 29; 55°C: 28; 60°C: 27; 65°C: 27; 70°C: 26 A
Ground-fault protection and monitoringNo grounding-protection function; ground-fault monitoring absent
Electrical endurance at 480 V8,000 operating cycles
Electrical endurance at 600 V4,000 operating cycles
Instantaneous short-circuit trip settingIi = 10 Ă— In, permanently set
Maximum power loss3 W
Operational current by ambient temperature29 A at 45 °C; 29 A at 50 °C; 28 A at 55 °C; 27 A at 60 °C; 27 A at 65 °C; 26 A at 70 °C

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral
Series TypeSENTRON 3VA4
Main-circuit connection arrangementInfeed: low tab; output: circular-conductor connection
Infeed-side main-circuit connectionLow tab
Output-side main-circuit connectionCircular conductor connection
Connectable conductor size1 conductor, 14–8 AWG, stranded round conductor
Auxiliary CO contacts0 contacts
Connection surface finishTin

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsUL Listed
UL 489 100%-rated breaker markingNo
Front protection classIP40