Skip to content

Siemens SENTRON 3VA4 3-Pole 50A 600VAC Circuit Breaker

0 Reviews
SKU
3VA4150-6ED34

The Siemens SENTRON 3VA4 3VA4150-6ED34 is a UL Listed, three-pole molded-case circuit breaker rated 50 A at 600 V AC, with a standard trip and bolt-on mounting.

  • 3-pole, 50 A rating
  • 600 V AC rating
  • UL 489 breaking capacity
  • Bolt-on mounting
  • Standard trip
  • UL Listed

The Siemens SENTRON 3VA4 3VA4150-6ED34 is a UL Listed, three-pole molded-case circuit breaker rated 50 A at 600 V AC, with a standard trip and bolt-on mounting.

Product Overview

The Siemens SENTRON 3VA4 3VA4150-6ED34 is a UL Listed, three-pole molded-case circuit breaker rated 50 A at 600 V AC, with a standard trip and bolt-on mounting.

  • 3-pole, 50 A rating
  • 600 V AC rating
  • UL 489 breaking capacity
  • Bolt-on mounting
  • Standard trip
  • UL Listed

Technical Specifications

Product information and specifications for the selected item.

SKU: 3VA4150-6ED34

Product Information

BrandSiemens
MPN3VA4150-6ED34
SKU3VA4150-6ED34
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)50
Voltage600 V AC
Interruption TypeStandard Trip
Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)50
Voltage600 V AC
Interruption TypeStandard Trip
Storage temperature range-40 to 80 °C
HACR ratingYes
UL 489 current breaking capacity at 480 V AC65 kA
HID ratingYes
Maximum power loss9.7 W
Electrical endurance at 600 V4,000 operating cycles
Overcurrent-release protection functionLI
UL 489 current breaking capacity at 600Y/347 V AC25 kA
Grounding protectionNo
Typical mechanical service life15,000 operating cycles
Electrical endurance at 480 V8,000 operating cycles
L-tripping delay time with I²t characteristic1 (minimum and maximum) s
SWD ratingNo
UL 489 current breaking capacity at 240 V AC100 kA
UL 489 current breaking capacity at 480Y/277 V AC65 kA
Ambient operating temperature range-25 to 70 °C
Operational current by ambient temperature45 °C: 49 A; 50 °C: 47 A; 55 °C: 46 A; 60 °C: 44 A; 65 °C: 43 A; 70 °C: 41 A
Short-circuit trip setting (Ii)Permanently set to 10 Ă— In

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypeNon-Neutral
Series Type3VA4
Bottom connection surface finishTin
Output-side main-current connectionCircular conductor connection
Infeed-side main-current connectionLow tab
Connectable stranded conductor range1 × 8–3/0 AWG

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsUL Listed
UL 489 100%-rated breaker markingNo
Front protection classIP40

Dimensions & Weight

Height (in.)5.0945
Width (in.)3
Length (in.)3.6339
Weight (lb.)1.638