586-554-2000
Mon–Fri 6:30am–5pm · Sat 8am–3pm
586-554-2000
Mon–Fri 6:30am–5pm
The Siemens SENTRON 3VA5 is a 100 A, three-pole molded-case circuit breaker with a 125 A frame and a 25 kA interrupting rating at 480 V. It has a TM230/FTAM T-M trip unit, a 690 V voltage rating, and is supplied without lugs.
The Siemens SENTRON 3VA5 is a 100 A, three-pole molded-case circuit breaker with a 125 A frame and a 25 kA interrupting rating at 480 V. It has a TM230/FTAM T-M trip unit, a 690 V voltage rating, and is supplied without lugs.
The Siemens SENTRON 3VA5 is a 100 A, three-pole molded-case circuit breaker with a 125 A frame and a 25 kA interrupting rating at 480 V. It has a TM230/FTAM T-M trip unit, a 690 V voltage rating, and is supplied without lugs.
Product information and specifications for the selected item.
| Brand | Siemens |
|---|---|
| MPN | 3VA5110-4EC31-0AA0 |
| SKU | 3VA5110-4EC31-0AA0 |
| UPC / GTIN | 804766301018 |
| Category | Circuit Breakers |
| Maximum Amperage (A) | 100 |
|---|---|
| Voltage | 690 V |
| Interruption Type | Standard Trip |
| Breaker Type | Standard |
| Mounting Type | Din Rail |
| Neutral Connection Type | Non-Neutral |
| Maximum Amperage (A) | 100 |
|---|---|
| Voltage | 690 V |
| Interruption Type | Standard Trip |
| Power loss per pole at rated current | 7.6 W/pole |
| IEC 60947 short-circuit making capacity (Icm) | 121 kA at 240 V; 75.6 kA at 415 V; 7.5 kA at 690 V |
| Storage temperature | -40 to 80 °C |
| Rated insulation voltage | 800 V |
| IEC 60947 maximum short-circuit breaking capacity (Icu) | 55 kA at 240 V; 36 kA at 415 V; 5 kA at 690 V |
| Operating ambient temperature | -25 to 70 °C |
| Electrical endurance | 8,000 cycles at AC-1 380/415 V; 4,000 at AC-1 690 V; 8,000 at 480 V; 4,000 at 600 V operating cycles |
| Maximum power loss | 22.8 W |
| Operational current at 70 °C | 87 A |
| UL 489 interrupting capacity at alternate voltages | 65 kA at 240 V; 14 kA at 600Y/347 V |
| Mechanical service life | 20,000 typical operating cycles |
| Breaker Type | Standard |
|---|---|
| Mounting Type | Din Rail |
| Neutral Connection Type | Non-Neutral |
| Series Type | 3VA5 |
| Overcurrent release and protection function | TM230; LI |
| Front protection class | IP40 |
| Main-current connection arrangement | Without connection |
| Main-circuit connector arrangement | Without connection |
| Instantaneous trip pickup range (Ii) | 500–1,000 A |
| Instantaneous trip setting range (Ii) | 500–1,000 A (5–10 × In) |
| Grounding protection | No |
| Reverse-feed application suitability | Suitable for reverse-feed applications |
| Ground-fault protection | No |
| Long-time trip delay (tr, I2t characteristic) | 1 s |
| Bundle/Single | Single Product |
|---|
| Certifications and Listings | cUL Listed, ROHS, UL Listed |
|---|---|
| UL 489 100%-rated breaker designation | No |
| 100%-rated breaker marking | No |
| UL 489 HACR type | Yes |
| Height (in.) | 5.51 |
|---|---|
| Width (in.) | 3 |
| Length (in.) | 3.72 |
| Weight (lb.) | 2.0944 |
Added to cart