Skip to content

Siemens SENTRON 3VA5 200A 3P MCCB, 250A Frame, Class M, TM230 T-M Trip, Without Lugs

0 Reviews
SKU
3VA5220-5EC31-0AA0

Siemens’ SENTRON 3VA5 is a 200 A, three-pole molded-case circuit breaker with a 250 A frame, Class M breaking capacity, and a TM230 thermal-magnetic trip unit. Its fixed Ir is 200 A and Ii is adjustable from 1,000 to 2,000 A. It is rated 690 V, with interrupting capacities of 35 kAIC at 480 V and 18 kAIC at 600 V; it is UL Listed and cUL Listed and is supplied without lugs.

  • 200 A Rating, 250 A Frame
  • Three-Pole Configuration
  • Class M Breaking Capacity
  • TM230 Thermal-Magnetic Trip
  • 690 V and AIC Ratings
  • Lugs Not Included

Product Overview

Siemens’ SENTRON 3VA5 is a 200 A, three-pole molded-case circuit breaker with a 250 A frame, Class M breaking capacity, and a TM230 thermal-magnetic trip unit. Its fixed Ir is 200 A and Ii is adjustable from 1,000 to 2,000 A. It is rated 690 V, with interrupting capacities of 35 kAIC at 480 V and 18 kAIC at 600 V; it is UL Listed and cUL Listed and is supplied without lugs.

Technical Specifications

Product information and specifications for the selected item.

SKU: 3VA5220-5EC31-0AA0

Product Information

BrandSiemens
MPN3VA5220-5EC31-0AA0
SKU3VA5220-5EC31-0AA0
UPC / GTIN4042948853849
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)200
Voltage690 V
Interruption TypeStandard Trip
Breaker TypeStandard
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)200
Voltage690 V
Interruption TypeStandard Trip
Minimum storage temperature-40 °C
Operational current at 55 °C183 A
Operational current at 60 °C178 A
Power loss per pole at rated current, AC hot operating state14.17 W
Minimum operating ambient temperature-25 °C
Electrical endurance at AC-1, 690 V4,000 operating cycles
Operational current at 65 °C172 A
Typical mechanical service life20,000 operating cycles
Electrical endurance at 600 V4,000 operating cycles
Maximum power loss43 W
Electrical endurance at 480 V8,000 operating cycles
Maximum storage temperature80 °C
Maximum operating ambient temperature70 °C
Operational current at 45 °C194 A
Operational current at 50 °C189 A
Electrical endurance at AC-1, 380/415 V8,000 operating cycles
Operational current at 70 °C167 A

Breaker Configuration

Breaker TypeStandard
Neutral Connection TypeNon-Neutral
Series Type3VA5
Changeover auxiliary contacts0 contacts
Overcurrent release protection functionLI
Grounding protectionNo
L-trip delay setting (tr)1 s
Instantaneous trip setting range (Ii)1,000–2,000 A

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingscUL Listed, UL Listed
UL 489 100%-rated breakerNo
Front protection classIP40

Dimensions & Weight

Height (in.)7.28
Width (in.)4.13
Length (in.)4.21
Weight (lb.)4.471

Product Documents

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.