The Siemens SENTRON 3VA5 is a three-pole molded-case circuit breaker rated 300 A on a 400 A frame, with a TM230 trip unit. Its Class H interrupting capacity is 65 kA at 480 V; it is rated 690 V AC and UL Listed.

  • 300 A Rating, 400 A Frame
  • Three-Pole Configuration
  • Class H, 65 kAIC at 480 V
  • 690 V AC Rating
  • TM230 Trip Settings
  • UL Listed

The Siemens SENTRON 3VA5 is a three-pole molded-case circuit breaker rated 300 A on a 400 A frame, with a TM230 trip unit. Its Class H interrupting capacity is 65 kA at 480 V; it is rated 690 V AC and UL Listed.

Product Overview

The Siemens SENTRON 3VA5 is a three-pole molded-case circuit breaker rated 300 A on a 400 A frame, with a TM230 trip unit. Its Class H interrupting capacity is 65 kA at 480 V; it is rated 690 V AC and UL Listed.

  • 300 A Rating, 400 A Frame
  • Three-Pole Configuration
  • Class H, 65 kAIC at 480 V
  • 690 V AC Rating
  • TM230 Trip Settings
  • UL Listed

Technical Specifications

Product information and specifications for the selected item.

SKU: 3VA5330-6EC31-0AA0

Product Information

BrandSiemens
MPN3VA5330-6EC31-0AA0
SKU3VA5330-6EC31-0AA0
UPC / GTIN804766793219
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)300
Voltage690 V
Interruption TypeStandard Trip
Breaker TypeStandard
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)300
Voltage690 V
Interruption TypeStandard Trip
Mechanical service life20,000 (typical) operating cycles
Overcurrent release protection functionLI
Storage temperature range-40 to 80 °C
Maximum power loss70 W
Operating ambient temperature range-25 to 70 °C
Long-time trip delay (tr, I2t characteristic)1 (fixed) s
Operational current by ambient temperature45 °C: 294 A; 50 °C: 288 A; 55 °C: 282 A; 60 °C: 276 A; 65 °C: 270 A; 70 °C: 264 A
100%-rated breaker markingNo
Ambient temperature during operation-25 to 70 °C
Ground-fault protectionNo
Grounding protectionNo
Long-time trip delay setting (tr)1 s
Power loss per pole at rated current in hot AC operation23.4 W
Electrical endurance at AC-1, 380/415 V6,000 switching cycles
Instantaneous trip pickup settings (Ii)1,500; 1,800; 2,100; 2,400; 2,700; 3,000 A
Ambient temperature during storage-40 to 80 °C

Breaker Configuration

Breaker TypeStandard
Neutral Connection TypeNon-Neutral
Series Type3VA5
Reverse-feed application suitabilitySuitable for reverse-feed applications
Auxiliary CO contacts0 contacts
Trip-circuit-breaker interchangeabilityNon-interchangeable
Main-current-circuit connectionWithout connection
Product designSystem protection
RapidSBx switchboard compatibilityCompatible as a 3VA5 thermal-magnetic trip-unit branch breaker
Included release and indication componentsNo undervoltage release, no voltage trigger, and no trip indicator

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsUL Listed
Front protection ratingIP40

Dimensions & Weight

Height (in.)9.76
Width (in.)5.43
Length (in.)4.33
Weight (lb.)10.4874

Product Documents

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.