Siemens Type VBII 200A 3-Pole 240V 4-Wire General-Duty Fusible Safety Switch with Neutral, Type 1

0 Reviews
SKU
GF324NA

The Siemens GF324NA is a fused indoor safety switch identified as 200 A, 3-pole, and 240 V. It is listed as suitable for service entrance use and for grounded B-phase systems, with mechanical lugs for #6 AWG–300 kcmil copper or aluminum line, load, and neutral conductors.

  • 200 A, 3-Pole, 240 V
  • Fused Indoor Safety Switch
  • Service-Entrance Suitability
  • Copper/Aluminum Lug Range
  • Short-Circuit Ratings by Fuse Class
  • Grounded B-Phase Compatibility

The Siemens GF324NA is a fused indoor safety switch identified as 200 A, 3-pole, and 240 V. It is listed as suitable for service entrance use and for grounded B-phase systems, with mechanical lugs for #6 AWG–300 kcmil copper or aluminum line, load, and neutral conductors.

Product Overview

The Siemens GF324NA is a fused indoor safety switch identified as 200 A, 3-pole, and 240 V. It is listed as suitable for service entrance use and for grounded B-phase systems, with mechanical lugs for #6 AWG–300 kcmil copper or aluminum line, load, and neutral conductors.

  • 200 A, 3-Pole, 240 V
  • Fused Indoor Safety Switch
  • Service-Entrance Suitability
  • Copper/Aluminum Lug Range
  • Short-Circuit Ratings by Fuse Class
  • Grounded B-Phase Compatibility

Technical Specifications

Product information and specifications for the selected item.

SKU: GF324NA

Product Information

BrandSiemens
SKUGF324NA
CategoryDisconnects & Safety Switches

Key Specs

Maximum Amperage (A)200
Phase Type3 Phase
Disconnect TypeSafety Switch
NEMA Enclosure RatingNEMA 1

Switch Ratings

Maximum Amperage (A)200
Phase Type3 Phase
Grounded B-phase compatibilityFor application on grounded B-phase systems
Short-circuit current rating10,000 with Class H fuses; 100,000 with Class R or T fuses AIC
Short-circuit interrupting rating10,000 AIC with Class H fuses; 100,000 AIC with Class R or T fuses
Horsepower ratings240 V AC, 1-phase/3-wire: 15 standard; 3-phase/3-wire: 25 standard, 60 maximum; 250 V DC: 40. Maximum applies with time-delay fuses. HP
Mechanical service life8,000 typical operating cycles

Disconnect Configuration

Disconnect TypeSafety Switch
FusedFused
Switch position indicationHighly visible ON/OFF indication
Neutral-ground wire range#14–1/0 AWG
Cover interlockSingle cover interlock
Terminal connectionMechanical lugs
Mechanical lug wire range (line, load, neutral)#6 AWG–300 kcmil for copper or aluminum conductors (60/75°C)
Blade constructionDouble-break visible blade design
Line/load/neutral conductor rangeLine, load, and neutral conductors: #6 AWG–300 kcmil Cu/Al (60/75 °C)
Neutral constructionSolid neutral
Switching actionQuick-make and break switching action
Fastening methodSurface

Enclosure & Certifications

NEMA Enclosure RatingNEMA 1
Certifications and ListingsUL Listed
Operating ambient temperature range-29 to 85 °C
Service entrance suitabilitySuitable for use as service entrance equipment
Enclosure material and thicknessCold-rolled steel, 0.054 in thick (17 gauge)
Enclosure finishANSI Grey #61 paint
Enclosure sheet thickness0.054 in (17 gauge)

Dimensions & Weight

Height (in.)31.07
Width (in.)16.68
Length (in.)10.92
Weight (lb.)41.689
Conduit knockout diameter0.88 in diameter, top and bottom
Wire-bend space (fused)Line side: 7.87 in (200 mm); load side: 10.34 in (263 mm) in (mm)
Ground knockout diameter0.25 in diameter, top and bottom
Tangential conduit knockout sizes1.25, 1.50, 2.00, and 2.50 in conduit sizes in (trade size)