The Siemens WP6512 is a five-position, ring-style Uni-PAK meter center for 120/240 V AC single-phase service, with a 600 A bus, 225 A maximum tenant main and no bypass. It has a NEMA 3R galvanized-steel enclosure, supports top- or bottom-fed service, and is specified for use only as service equipment.
The Siemens WP6512 is a five-position, ring-style Uni-PAK meter center for 120/240 V AC single-phase service, with a 600 A bus, 225 A maximum tenant main and no bypass. It has a NEMA 3R galvanized-steel enclosure, supports top- or bottom-fed service, and is specified for use only as service equipment.
The Siemens WP6512 is a five-position, ring-style Uni-PAK meter center for 120/240 V AC single-phase service, with a 600 A bus, 225 A maximum tenant main and no bypass. It has a NEMA 3R galvanized-steel enclosure, supports top- or bottom-fed service, and is specified for use only as service equipment.
Product information and specifications for the selected item.
| Brand | Siemens |
|---|---|
| MPN | WP6512 |
| SKU | WP6512 |
| UPC / GTIN | 040892875539 |
| Category | Meter Stacks |
| Meter Stack Amperage Rating (A) | 600 A |
|---|---|
| NEMA Enclosure Rating | NEMA 3R |
| Phase | 1 |
| Voltage Rating | 120/240 V AC |
| Type | 5-Position |
| Meter Stack Amperage Rating (A) | 600 A |
|---|---|
| Voltage Rating | 120/240 V AC |
| Phase | 1 |
| Service-equipment suitability | Suitable only for use as service equipment |
| Maximum AIC | 100,000 A |
| N2/G terminal torque | 275 lb-in |
| Maximum short-circuit current rating | 100,000 RMS symmetrical |
| Top-right breaker position maximum | 200 A |
| Top-right branch breaker maximum | 200 A |
| Overload-trip indication and reset | An overload trip is indicated by the handle midway between ON and OFF; reset by moving it to OFF, then ON |
| A/B/N1 terminal torque | 375 lb-in |
| Equipment grounding terminal torque | 110 lb-in |
| Type | 5-Position |
|---|---|
| Supported breaker types | QP, QPH, HQP, MP-T, MP-HT, MP-MT, QS, QSH, QSHH, HQS, HQSH |
| Line lug configuration | Al/Cu lay-in lugs |
| Conductor material and temperature requirements | Copper or aluminum, 60/75°C; observe breaker markings at breaker terminals |
| Permitted circuit breaker types | Siemens QS, QSH, QSHH, HQS, HQSH, QP, QPH, HQP, HQPH, MP-T, MP-HT, and MP-MT |
| Conductor temperature listing | UL listed for 60/75°C conductors; consult equipment markings for application |
| Feed direction | Top or bottom feed |
| Branch wiring exit locations | Branch wiring exits at the bottom and rear; neutral and ground exit at the bottom only |
| 125 A breaker compatibility | Standard 125 A breakers accepted |
| Maximum main disconnecting means | 6 |
| Service-feed options | Overhead or underground service |
| NEMA Enclosure Rating | NEMA 3R |
|---|---|
| Material | Galvanized Steel |
| Knockout plate | Removable |
| Mounting method | Surface-mounted |
| Finish | ANSI #61 light gray electrodeposited paint |
| Interior chemical exposure | Keep petroleum-based sprays, chemicals, solvents, and paint away from interior components |
| Unmetered compartment | Barriered, sealable compartment for unmetered current-carrying parts |
| Height (in.) | 39.63 |
|---|---|
| Width (in.) | 46.47 |
| Length (in.) | 9 |