The Siemens HF366NRA is a 600 A, 3-pole, 600 V fused heavy-duty outdoor safety switch with single-throw, quick-make-and-break action. It is specified as suitable for use as service-entrance equipment.

  • 600 A, 3-Pole, 600 V
  • Fused Outdoor Safety Switch
  • 10,000 AIC Standard Rating
  • Service-Entrance Suitability
  • Line/Load Lug Wire Range
  • 100% Neutral Wire Range

Product Overview

The Siemens HF366NRA is a 600 A, 3-pole, 600 V fused heavy-duty outdoor safety switch with single-throw, quick-make-and-break action. It is specified as suitable for use as service-entrance equipment.

Technical Specifications

Product information and specifications for the selected item.

SKU: HF366NRA

Product Information

BrandSiemens
SKUHF366NRA
CategoryDisconnects & Safety Switches

Key Specs

Maximum Amperage (A)600
Phase Type3 Phase
Disconnect TypeSafety Switch
NEMA Enclosure RatingNEMA 3R

Switch Ratings

Maximum Amperage (A)600
Phase Type3 Phase
Overload current rating12X
Short-circuit rating10,000 AIC standard; 200,000 AIC with Class R, T or J fuses rated 400 A maximum
I²t rating6,000,000 A²·s

Disconnect Configuration

Disconnect TypeSafety Switch
FusedFused
Line/load lug wire range(1) 1/0 AWG–750 kcmil or (2) 1/0 AWG–500 kcmil AWG/kcmil
Switching mechanismQuick-make and break switching action
Fuse clip constructionSpring-loaded heat-sink fuse clip
Cover interlockDefeatable dual cover interlock
Line/load base designOne-piece line and load base for phase-to-phase alignment
100% neutral wire range(2) 1/0–600 kcmil or (2) 6–300 kcmil AWG/kcmil
Neutral grounding provisionExtra ground lug on neutral
Switch actionSingle throw
Blade visibilityVisible blade design
Electrical connectionMechanical lugs
Position indicationHighly visible ON/OFF indication

Enclosure & Certifications

NEMA Enclosure RatingNEMA 3R
Certifications and ListingsUL Listed
Enclosure materialGalvanized steel
Enclosure finishANSI Grey #61 paint
Service-entrance suitabilitySuitable for use as service entrance equipment
Tangential knockout placementBottom-only tangential knockouts
Mounting methodSurface
Enclosure thickness0.060 (16 gauge) in.
Operating ambient temperature range-29 to 85 °C
Wire-bending spaceMeets NEC wire bending space requirements
Ground knockout size and placement0.50–0.75 diameter; bottom-only placement in.
Tangential conduit knockout sizes2.00, 2.50, 3.00, 3.50 in.

Dimensions & Weight

Height (in.)45.81
Width (in.)23.404
Length (in.)9.93
Weight (lb.)100