Southwire 10/2 NM-B (Romex) CableAdditional specifications Additional specifications · Compliance Federal specification reference A-A-59544 RoHS compliance RoHS-2 (European Directive 2011/65/EU) UL product standard UL 719 — Nonmetallic-Sheathed Cables Conductor wire standard ASTM B3 NOM safety standard NOM-063-SCFI — Electrical Products – Condu...

Needs Data

Product Overview

Southwire 10/2 NM-B (Romex) Cable

Additional specifications

Additional specifications · Compliance

Federal specification reference A-A-59544
RoHS compliance RoHS-2 (European Directive 2011/65/EU)
UL product standard UL 719 — Nonmetallic-Sheathed Cables
Conductor wire standard ASTM B3
NOM safety standard NOM-063-SCFI — Electrical Products – Conductors – Safety Requirements

Additional specifications · Electrical

AC resistance at 75°C 1.291 Ω/1000 ft
Inductive reactance at 60 Hz 0.05 Ω/1000 ft
Allowable ampacity and overcurrent limit 30 at 60°C; NEC 240.4(D) protection limit is also 30.
Voltage rating 600 V
Lighting-fixture termination rating Individual conductor insulation is rated 90°C for terminations in lighting fixtures.
Individual conductor insulation temperature rating 90 °C
DC resistance at 25°C 1.04 Ω/1000 ft

Additional specifications · Applications

Primary application Primarily residential branch circuits for outlets, switches, and other loads.

Additional specifications · Construction

Insulated conductor colors Black and white
Jacket material Polyvinyl chloride (PVC)
Binder material Kraft paper
Insulation construction PVC insulation with a nylon sheath
Ground conductor wrapping Kraft paper wrap

Additional specifications · Installation

Panelboard and box termination Conductors without the cable jacket routed in panelboards or boxes for termination are considered part of the complete NM-B cable.
Minimum bending radius 0.9 in
Masonry wall installation May run in air voids of masonry block or tile walls when those walls are not wet or damp.
Permitted installation locations Exposed or concealed work in dry locations
Installation location and temperature limit Exposed or concealed in normally dry locations up to 90°C; ampacity limited to 60°C conductor values.
Separate-conductor installation restriction Internal conductors are not listed or marked as THHN (or another NEC-recognized conductor type) and must not be installed apart from the complete Type NM-B cable.

Technical Specifications

Product information and specifications for the selected item.

SKU: 10/2 ROMEX

Product Information

BrandSouthwire
MPN10/2 ROMEX
SKU10/2 ROMEX
CategoryNM-B Cable

Key Specs

Wire Gauge10/2
Conductor MaterialCopper
Stranded or SolidSolid
Jacket ColorOrange

Electrical & Conductor

Wire Gauge10/2
Conductor MaterialCopper
Stranded or SolidSolid

Package & Length

Bundle/SingleSingle Product

Jacket & Features

Jacket ColorOrange
FeaturesJacketed

Dimensions & Weight

Height (in.)0.21
Width (in.)0.505