Skip to content

10/3 NM-B (Romex) Cable

0 Reviews
SKU
10/3 ROMEX PER FOOT

Southwire Romex® SIMpull® Type NM-B cable is 10/3 AWG with three insulated solid-copper conductors and a bare copper ground. Rated 600 V for dry-location work, it has a pink PVC jacket and is sold by the foot.

  • 10/3 Type NM-B Cable
  • Solid Copper Conductors
  • 600 V Rating
  • Pink PVC Jacket
  • Dry-Location Use
  • Cut by the Foot

Product Overview

Southwire Romex® SIMpull® Type NM-B cable is 10/3 AWG with three insulated solid-copper conductors and a bare copper ground. Rated 600 V for dry-location work, it has a pink PVC jacket and is sold by the foot.

Technical Specifications

Product information and specifications for the selected item.

SKU: 10/3 ROMEX PER FOOT

Product Information

BrandSouthwire
MPN10/3 ROMEX PER FOOT
SKU10/3 ROMEX PER FOOT
CategoryNM-B Cable

Key Specs

Wire Gauge10/3
Total Wire Length (ft.)1
Conductor MaterialCopper
Stranded or SolidSolid
Jacket ColorPink

Electrical & Conductor

Wire Gauge10/3
Conductor MaterialCopper
Stranded or SolidSolid
Conductor wire specificationASTM B3 — soft or annealed copper wire
Allowable ampacity and application limit30 A at 60°C and 40 A at 90°C per Table 2. Use ampacity is limited to the 60°C-conductor basis; NEC 240.4(D) limits overcurrent protection for 10 AWG copper to 30 A.
Individual conductor insulation temperature rating90°C, for terminations in lighting fixtures
Ampacity basisBased on 2023 NEC Table 310.16
Conductor insulation constructionPVC insulation with a nylon sheath
Allowable ampacity at 90°C (table value)40 A
Inductive reactance0.05 at 60 Hz; basis is non-ferrous conduit with one-diameter center-to-center spacing. Ω/1000 ft
Voltage rating600 V
AC resistance at 75°C1.291 Ω/1000 ft
NEC 240.4(D) overcurrent-protection limitation30 A
Ground wire wrapKraft paper wrap
Allowable ampacity at 60°C30 A
Phase-conductor insulation color codeBlack, red, and white
DC resistance at 25°C1.04 Ω/1000 ft

Package & Length

Bundle/SingleSingle Product
Total Wire Length (ft.)1
Wire Cut TypeCut By-The-Foot

Jacket & Features

Jacket ColorPink
FeaturesJacketed
Individual conductor installation restrictionsIndividual conductors are not listed or marked as THHN or another NEC-recognized conductor type and must not be installed apart from the complete Type NM-B cable. Conductors routed inside panelboards or boxes without the jacket for termination are considered part of the complete cable.
RoHS specificationRoHS-2 (European Directive 2011/65/EU)
Typical applicationPrimarily used in residential wiring as branch circuits for outlets, switches, and other loads.
Jacket materialPolyvinyl chloride (PVC)
Permitted installation locationsSuitable for exposed or concealed work in dry locations; may be run in masonry-block or tile-wall air voids only where the walls are not wet or damp.
NOM safety standardNOM-063-SCFI — Electrical Products – Conductors – Safety Requirements
UL product standardUL 719 — Nonmetallic-Sheathed Cables
Binder materialKraft paper
Federal specificationA-A-59544

Dimensions & Weight

Height (in.)0.63
Length (in.)12
Weight (lb.)0.167
Minimum bending radius0.9 in

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.