Skip to content

12/2/2 NM-B (Romex) Cable

0 Reviews
SKU
12/2/2 ROMEX 250

Southwire Romex SIMpull 12/2/2 Type NM-B cable contains four solid 12 AWG copper conductors and a 12 AWG bare copper ground under a yellow PVC outer jacket. It is rated for 600 V, supplied in a 250 ft pre-cut length, and specified for exposed or concealed work in normally dry locations.

  • Four Solid 12 AWG Copper Conductors
  • 12 AWG Bare Copper Ground
  • 600 V Voltage Rating
  • 20 A Allowable Ampacity
  • 250 ft Pre-Cut Length
  • Yellow PVC Outer Jacket

Product Overview

Southwire Romex SIMpull 12/2/2 Type NM-B cable contains four solid 12 AWG copper conductors and a 12 AWG bare copper ground under a yellow PVC outer jacket. It is rated for 600 V, supplied in a 250 ft pre-cut length, and specified for exposed or concealed work in normally dry locations.

Technical Specifications

Product information and specifications for the selected item.

SKU: 12/2/2 ROMEX 250

Product Information

BrandSouthwire
MPN12/2/2 ROMEX 250
SKU12/2/2 ROMEX 250
CategoryNM-B Cable

Key Specs

Wire Gauge12/4
Total Wire Length (ft.)250
Conductor MaterialCopper
Jacket ColorYellow

Electrical & Conductor

Wire Gauge12/4
Conductor MaterialCopper
DC resistance at 25°C1.662 Ω/1000 ft
AC resistance at 75°C2.002 Ω/1000 ft
Conductor standard referenceASTM B3
Voltage rating600 V
Conductor insulation constructionPolyvinyl chloride (PVC) with nylon sheath
Individual conductor insulation temperature rating90 °C
Ampacity temperature basis60 °C
Allowable ampacity (manufacturer table)20 A
Ground-wire wrapKraft paper wrap
2/2 conductor color codeBlack, white, red, and white with red stripe
Inductive reactance at 60 Hz0.054 Ω/1000 ft
Insulated conductor count4 conductors

Package & Length

Bundle/SingleSingle Product
Total Wire Length (ft.)250
Wire Cut TypePre-Cut Length

Jacket & Features

Jacket ColorYellow
FeaturesJacketed
Permitted installation conditionsExposed or concealed work in normally dry locations
RoHS referenceRoHS-2 (European Directive 2011/65/EU)
Individual-conductor installation restrictionIndividual conductors must not be installed apart from the complete Type NM-B cable
Maximum pull tension167 lb
Referenced federal specificationFederal Specification A-A-59544
Outer jacket materialPolyvinyl chloride (PVC)
Typical applicationBranch circuits for outlets, switches, and other loads
Masonry-wall useMay be run in air voids of masonry block or tile walls where the walls are not wet or damp
Nonmetallic-sheathed cable standardUL 719
Jacket thickness30 mils

Dimensions & Weight

Height (in.)4
Width (in.)13
Length (in.)13
Weight (lb.)32.966
Minimum bending radius1.6 in
Approximate cable outer diameter0.395 in