Skip to content

12/2 MC Hospital Grade Stranded Cable

0 Reviews
SKU
12-2 MC STR HCF-FT

Southwire MC-AP HCF Type MC cable is an indoor 12/2 AWG cable with stranded copper circuit conductors, THHN/THWN insulation, green interlocked aluminum armor, and a full-sized aluminum equipment grounding/bonding conductor. The specified cable length is 250 ft, and the manufacturer data includes installation conditions for patient-care branch circuits.

  • 12/2 AWG Stranded Copper
  • 600 V Cable Rating
  • THHN/THWN Insulation
  • Green Interlocked Aluminum Armor
  • Full-Sized Aluminum Ground
  • MCI-A Fitting Compatibility

Product Overview

Southwire MC-AP HCF Type MC cable is an indoor 12/2 AWG cable with stranded copper circuit conductors, THHN/THWN insulation, green interlocked aluminum armor, and a full-sized aluminum equipment grounding/bonding conductor. The specified cable length is 250 ft, and the manufacturer data includes installation conditions for patient-care branch circuits.

Technical Specifications

Product information and specifications for the selected item.

SKU: 12-2 MC STR HCF-FT

Product Information

BrandSouthwire
MPN12-2 MC STR HCF-FT
SKU12-2 MC STR HCF-FT
CategoryMC Cable & Armored Cable

Key Specs

Wire Gauge12/2
Maximum Amperage (A)30
Conductor MaterialCopper
Total Wire Length (ft.)250
Indoor/OutdoorIndoor

Electrical & Conductor

Wire Gauge12/2
Maximum Amperage (A)30
Conductor MaterialCopper
Conductor strand count19 strands
Redundant grounding pathBare 8000 series aluminum grounding/bonding conductor and armor
AC resistance at 75°C2.063 Ω/1000 ft
THHN/THWN dry temperature rating90 °C (dry)
Equipment grounding/bonding conductorFull-sized aluminum equipment grounding/bonding conductor
UL-listed voltage rating600 V
Insulated ground constructionGreen-insulated PVC with nylon sheath, THHN/THWN
Phase conductor insulationPolyvinyl chloride with nylon sheath, THHN/THWN
DC resistance at 25°C1.662 Ω/1000 ft
Inductive reactance at 60 Hz0.054 Ω/1000 ft
Voltage designation in product title120/208 V

Ratings & Features

Indoor/OutdoorIndoor
FeaturesHeat Resistant
Minimum bend radius3.7 in
Hazardous-location suitabilityClass I Division 2; Class II Division 2; Class III Division 1
Compatible fittingsUL-listed MCI-A fittings
Patient-care installation conditionsInstall patient-care branch circuits per NEC Articles 517 and 330, with mechanical protection per Article 300.4
Binder materialMylar tape
Environmental directiveRoHS-2, European Directive 2011/65/EU
Armor constructionGreen aluminum interlocked armor
Metal-clad cable standardUL 1569 — Metal-Clad Cables
Use restrictionUse is prohibited in hazardous anesthetizing areas
FT4 vertical-tray fire testsUL 1685 FT4 and IEEE 1202 FT4; IEEE test specified at 70,000 BTU/hr
Firestop-system use listingListed for UL 1-, 2-, and 3-hour through-penetration firestop systems
Insulated-wire standardUL 83 — Thermoplastic Insulated Wires and Cables
Flame ratingVW1

Length & Packaging

Total Wire Length (ft.)250

Dimensions & Weight

Height (in.)6
Width (in.)14
Length (in.)14
Weight (lb.)33.83