12 AWG THHN/THWN-2 Stranded Copper Wire

0 Reviews
SKU
12THHN-STR-BLK-FT

Southwire 12 AWG THHN/THWN-2 Stranded Copper WireAdditional specifications Additional specifications · Electrical AC Resistance at 75°C 2.063 Ω/1000 ft Inductive Reactance at 60Hz 0.054 Ω/1000 ft Voltage Rating 600 V DC Resistance at 25°C 1.662 Ω/1000 ft Additional specifications · Compliance UL Standard UL 83 Thermoplastic Insulated Wires ...

Needs Data

Product Overview

Southwire 12 AWG THHN/THWN-2 Stranded Copper Wire

Additional specifications

Additional specifications · Electrical

AC Resistance at 75°C 2.063 Ω/1000 ft
Inductive Reactance at 60Hz 0.054 Ω/1000 ft
Voltage Rating 600 V
DC Resistance at 25°C 1.662 Ω/1000 ft

Additional specifications · Compliance

UL Standard UL 83 Thermoplastic Insulated Wires and Cables, UL 758 Standard for Appliance Wiring Material, UL 1063 Machine Tool Wiring (MTW)
Cable Standard ICEA S-95-658 (NEMA WC70)
CSA Standard CSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables
Federal Specification Federal Specification A-A-59544
Domestic-Preference Standard NEMA 70901-2-2024 Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable
Mexican Standard NMX-J-010-ANCE Thermoplastic insulated wires and cables

Additional specifications · Operating Conditions

AWM temperature limit Dry locations: not to exceed 105; only when rated and used as appliance wiring material °C
MTW temperature limits Wet or oil-exposed: not to exceed 60; dry: not to exceed 90 °C
THWN-2 Wet-Location Temperature Limit 90 °C
THHN Dry-Location Temperature Limit 90 °C

Additional specifications · Construction

Insulation Material Polyvinyl chloride (PVC)
Stranding Construction Combination Unilay-Stranded
Sheath Material Nylon
Jacket Thickness 5 mil
Insulation Thickness 16 mil
Number of conductors 1 conductor

Additional specifications · Installation

Minimum Bending Radius 0.5 inch
Recommended Application Conduit branch circuits in commercial or industrial applications, per the NEC and applicable codes

Additional specifications · Application

Intended application Primarily used in conduit for branch circuits in commercial or industrial applications

Additional specifications · Standards

Conductor Standard ASTM B3, ASTM B787

Technical Specifications

Product information and specifications for the selected item.

SKU: 12THHN-STR-BLK-FT

Product Information

BrandSouthwire
MPN12THHN-STR-BLK-FT
SKU12THHN-STR-BLK-FT
CategoryCopper Building Wire

Key Specs

Wire Gauge12/19
Maximum Amperage (A)30
Conductor MaterialCopper

Electrical & Conductor

Wire Gauge12/19
Maximum Amperage (A)30
Conductor MaterialCopper

Cable Details

Jacket ColorBlack
FeaturesHeat Resistant, Jacketed

Dimensions & Weight

Height (in.)0.132
Width (in.)0.132