Skip to content

12 AWG THHN/THWN-2 Stranded Copper Wire

0 Reviews
SKU
12THHN-STR-WHT-FT

Southwire 12 AWG THHN/THWN-2 Stranded Copper WireAdditional specifications Additional specifications · Electrical AC Resistance at 75°C 2.063 Ω/1000 ft Inductive Reactance at 60Hz 0.054 Ω/1000 ft Voltage Rating 600 V DC Resistance at 25°C 1.662 Ω/1000 ft Additional specifications · Compliance UL Standard UL 83 Thermoplastic Insulated Wires ...

Needs Data

Product Overview

Southwire 12 AWG THHN/THWN-2 Stranded Copper Wire

Additional specifications

Additional specifications · Electrical

AC Resistance at 75°C 2.063 Ω/1000 ft
Inductive Reactance at 60Hz 0.054 Ω/1000 ft
Voltage Rating 600 V
DC Resistance at 25°C 1.662 Ω/1000 ft

Additional specifications · Compliance

UL Standard UL 83 Thermoplastic Insulated Wires and Cables, UL 758 Standard for Appliance Wiring Material, UL 1063 Machine Tool Wiring (MTW)
Cable Standard ICEA S-95-658 (NEMA WC70)
CSA Standard CSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables
Federal Specification Federal Specification A-A-59544
Domestic-Preference Standard NEMA 70901-2-2024 Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable
Mexican Standard NMX-J-010-ANCE Thermoplastic insulated wires and cables

Additional specifications · Operating Conditions

AWM temperature limit Dry locations: not to exceed 105; only when rated and used as appliance wiring material °C
MTW temperature limits Wet or oil-exposed: not to exceed 60; dry: not to exceed 90 °C
THWN-2 Wet-Location Temperature Limit 90 °C
THHN Dry-Location Temperature Limit 90 °C

Additional specifications · Construction

Insulation Material Polyvinyl chloride (PVC)
Stranding Construction Combination Unilay-Stranded
Sheath Material Nylon
Jacket Thickness 5 mil
Insulation Thickness 16 mil
Number of conductors 1 conductor

Additional specifications · Installation

Minimum Bending Radius 0.5 inch
Recommended Application Conduit branch circuits in commercial or industrial applications, per the NEC and applicable codes

Additional specifications · Application

Intended application Primarily used in conduit for branch circuits in commercial or industrial applications

Additional specifications · Standards

Conductor Standard ASTM B3, ASTM B787

Technical Specifications

Product information and specifications for the selected item.

SKU: 12THHN-STR-WHT-FT

Product Information

BrandSouthwire
MPN12THHN-STR-WHT-FT
SKU12THHN-STR-WHT-FT
CategoryCopper Building Wire

Key Specs

Wire Gauge12/19
Maximum Amperage (A)30
Conductor MaterialCopper

Electrical & Conductor

Wire Gauge12/19
Maximum Amperage (A)30
Conductor MaterialCopper
Voltage Rating600 V
AWM temperature limitDry locations: not to exceed 105; only when rated and used as appliance wiring material °C
Stranding ConstructionCombination Unilay-Stranded
DC Resistance at 25°C1.662 Ω/1000 ft
MTW temperature limitsWet or oil-exposed: not to exceed 60; dry: not to exceed 90 °C
AC Resistance at 75°C2.063 Ω/1000 ft
THHN Dry-Location Temperature Limit90 °C
Conductor StandardASTM B3, ASTM B787
Number of conductors1 conductor
Inductive Reactance at 60Hz0.054 Ω/1000 ft
THWN-2 Wet-Location Temperature Limit90 °C

Cable Details

Jacket ColorWhite
FeaturesHeat Resistant, Jacketed
Jacket Thickness5 mil
Sheath MaterialNylon
Insulation Thickness16 mil
Minimum Bending Radius0.5 inch
Recommended ApplicationConduit branch circuits in commercial or industrial applications, per the NEC and applicable codes
Insulation MaterialPolyvinyl chloride (PVC)
CSA StandardCSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables
UL StandardUL 83 Thermoplastic Insulated Wires and Cables, UL 758 Standard for Appliance Wiring Material, UL 1063 Machine Tool Wiring (MTW)
Cable StandardICEA S-95-658 (NEMA WC70)
Mexican StandardNMX-J-010-ANCE Thermoplastic insulated wires and cables
Federal SpecificationFederal Specification A-A-59544
Intended applicationPrimarily used in conduit for branch circuits in commercial or industrial applications
Domestic-Preference StandardNEMA 70901-2-2024 Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable

Dimensions & Weight

Height (in.)0.132
Width (in.)0.132

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.