4/0-3 Aluminum MC Cable

0 Reviews
SKU
4/0-3 #2G AL MC

Southwire Armorlite AlumaFlex Type MC feeder cable has three 4/0 AWG aluminum conductors insulated with THHN/THWN-2, a #2 bare aluminum ground, and aluminum interlocked armor. The listed specifications give a 600 V rating, 205 A maximum, 90°C dry / 75°C wet temperature rating, and indoor/outdoor use.

  • Three 4/0 AWG Aluminum Conductors
  • #2 Bare Aluminum Ground
  • 205 A Maximum Current
  • 600 V Rating
  • 90°C Dry / 75°C Wet Rating
  • Aluminum Interlocked Armor

Product Overview

Southwire Armorlite AlumaFlex Type MC feeder cable has three 4/0 AWG aluminum conductors insulated with THHN/THWN-2, a #2 bare aluminum ground, and aluminum interlocked armor. The listed specifications give a 600 V rating, 205 A maximum, 90°C dry / 75°C wet temperature rating, and indoor/outdoor use.

Technical Specifications

Product information and specifications for the selected item.

SKU: 4/0-3 #2G AL MC

Product Information

BrandSouthwire
MPN4/0-3 #2G AL MC
SKU4/0-3 #2G AL MC
CategoryMC Cable & Armored Cable

Key Specs

Maximum Amperage (A)205
Conductor MaterialAluminum & Copper
Indoor/OutdoorIndoor, Outdoor

Electrical & Conductor

Maximum Amperage (A)205
Conductor MaterialAluminum & Copper
AC resistance at 75°C0.105 Ω/1000 ft
Conductor strand count19 strands
Phase color code3/C: black, red, white
DC resistance at 25°C0.084 Ω/1000 ft
Voltage rating600 V
Conductor constructionClass B compact stranded; per ASTM B800 and ASTM B801
Inductive reactance at 60 Hz0.041 Ω/1000 ft

Ratings & Features

Indoor/OutdoorIndoor, Outdoor
FeaturesHeat Resistant
Minimum bend radius11 in
Maximum cable pull tension3808 lb
Air-handling space suitabilityEnvironmental air-handling spaces per NEC 300.22(C)
Code and federal specification complianceFederal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330
Insulation thickness50 mils
Flame ratingVW-1
Armor constructionAluminum interlocked armor
Temperature rating90 dry / 75 wet °C
Raised-floor suitabilityUnder raised floors for information-technology equipment conductors and cables per NEC 645.5(D) and 645.5(E)
UL and fire-test standardsUL 83; UL 1569; UL 1479; UL 1685 FT4; IEEE 1202 FT4
Firestop system listingUL 1-, 2- and 3-hour through-penetration firestop systems
Insulation typeTHHN/THWN-2 insulated singles
Binder materialMylar tape
Installation compatibilitySuitable for cable tray and approved raceways, or as aerial cable on a messenger
Hazardous-location suitabilityClass I Div. 2; Class II Div. 2; Class III Div. 1
Product listingUL Listed
Insulation constructionPolyvinyl chloride with nylon sheath