{"product_id":"southwire-4-awg-bare-copper-wire-stranded","title":"4 AWG Bare Copper Wire, Stranded","description":"\u003cp\u003eSouthwire 4 AWG Bare Copper Wire, Stranded\u003c\/p\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Standards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplicable standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B3 (soft or annealed copper wire); ASTM B8 (concentric-lay-stranded copper conductors)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Applications and Features\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCopper material properties\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eElectrolytic Tough Pitch copper, UNS C11000; at least 99.9% copper purity; soft-drawn copper conductivity of 100% IACS at 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eSuitable applications\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eClass B and C flexible stranded designs are suitable for uninsulated connections, jumpers, grounding, and insulated cable use in general wiring and underground systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Bare Copper Wire and Cable specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAllowable ampacity\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e170 A (75°C conductor temperature, 25°C ambient temperature, 2 ft\/s wind in sun)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStrand class\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApproximate conductor weight per length\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e128 lb\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor strand count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e7 strands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Table 1 – Physical and Electrical Data\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eRated strength\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e333 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDC resistance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.258 Ω\/1000 ft at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApproximate conductor outside diameter\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.225 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor cross-sectional area\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e41,740 cmil (26.93 mm²) cmil; mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAC resistance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.310 Ω\/1000 ft at 75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Product description\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCopper temper\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSoft-drawn copper\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Per ft","offer_id":68346354958447,"sku":"4 BARE STR PER FT","price":3.02,"currency_code":"USD","in_stock":true},{"title":"200 ft","offer_id":68193389871215,"sku":"4BARE STR SPOOL-200FT","price":349.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/registry-image-92bad9e740a7b198823b6a9f7f2698ccdf34d5844b4955c69609f8399b5f4195.jpg?v=1794578399","url":"https:\/\/excelele.com\/products\/southwire-4-awg-bare-copper-wire-stranded","provider":"Excel Lighting \u0026 Electrical Supply, Co.","version":"1.0","type":"link"}