Skip to content

750 kcmil XHHW-2 Stranded Aluminum Wire

0 Reviews
SKU
750MCM-XHHW-AL-YEL-FT

Southwire 750 kcmil XHHW-2 Stranded Aluminum WireAdditional specifications Additional specifications · Fire Performance Flame-Test Rating FT4 for sizes 350 kcmil and larger. Additional specifications · Construction Insulation Property Flame-retardant and moisture-resistant. Insulation Thickness 80 mil Conductor Count 1 Insulation Performance ...

Needs Data

Product Overview

Southwire 750 kcmil XHHW-2 Stranded Aluminum Wire

Additional specifications

Additional specifications · Fire Performance

Flame-Test Rating FT4 for sizes 350 kcmil and larger.

Additional specifications · Construction

Insulation Property Flame-retardant and moisture-resistant.
Insulation Thickness 80 mil
Conductor Count 1
Insulation Performance Flame-retardant and moisture-resistant.

Additional specifications · Compatibility

Health-Care Facility Suitability Suitable for health-care facilities where a dielectric constant of 3.5 or less is specified (NEC 517.160).
Healthcare Facility Suitability Suitable for healthcare-facility use where a dielectric constant of 3.5 or less may be specified.

Additional specifications · Mechanical

Minimum Bending Radius 5.4 inch
Maximum Pull Tension 4500 lb

Additional specifications · Operating Conditions

Wet/Dry Location Suitability Suitable for wet or dry locations.

Additional specifications · Environmental Resistance

Gas and Oil Resistance Gas and oil resistant II.
Sunlight Resistance Sunlight resistant for sizes 6 AWG and larger.

Additional specifications · Electrical

AC Resistance at 75°C 0.03 Ω/1000ft
DC Resistance at 25°C 0.023 Ω/1000ft
Inductive Reactance at 60 Hz 0.038 Ω/1000ft

Additional specifications · Installation

Pulling Lubricant Requirement Can be installed without pulling lubricant.
Open Wiring and Raceway Use Open wiring and raceways except cable troughs and ventilated flexible cableways, in dry or wet locations; open wiring exposed to weather.
Minimum Bend Radius 5.4 in
Raceway/Open-Wiring Suitability Open wiring and raceway use, except cable troughs and ventilated flexible cableways, per the Canadian Electrical Code.
Weather Exposure Suitable for open wiring exposed to the weather.

Additional specifications · Applications

Typical Applications Conduit and cable-tray runs for services, feeders, and branch circuits in commercial or industrial applications.

Additional specifications · Application

Intended Use Service, feeder, and branch-circuit wiring in conduit or cable trays.

Additional specifications · Installation Ratings

Cable Tray Rating CT rated for sizes 1/0 AWG and larger.

Technical Specifications

Product information and specifications for the selected item.

SKU: 750MCM-XHHW-AL-YEL-FT

Product Information

BrandSouthwire
MPN750MCM-XHHW-AL-YEL-FT
SKU750MCM-XHHW-AL-YEL-FT
CategoryAluminum Building Wire

Key Specs

Conductor Size750 KCMIL
Temperature Rating90 Deg C (Wet/Dry)
Voltage Rating600 V
Conductor MaterialAluminum Alloy
TypeXHHW-2

Electrical Ratings

Temperature Rating90 Deg C (Wet/Dry)
Voltage Rating600 V

Conductor & Cable

Conductor MaterialAluminum Alloy
Conductor Size750 KCMIL
Stranding61
TypeXHHW-2
Outer Diameter1068 mil

Insulation & Approval

Insulation MaterialCross-Linked Polyethylene
Insulation ColorYellow
ApprovalUL, UL 44

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.