Square D Homeline 50A 2-Pole Class A GFCI Circuit Breaker

0 Reviews
SKU
HOM250GFI

The Square D HOM250GFI is a Homeline miniature circuit breaker with a 50 A, two-pole configuration and a 120/240 V AC rating. It provides Class A 6 mA GFCI protection with a 10 kA interrupting rating, uses plug-on mounting with a pigtail neutral, and is specified for Homeline electrical panels and CSEDs.

  • 50 A, Two-Pole Rating
  • Class A, 6 mA GFCI
  • 120/240 V AC Rating
  • Homeline Panel/CSED Compatibility
  • 10 kA Interrupting Rating
  • Plug-On with Pigtail Neutral

Product Overview

The Square D HOM250GFI is a Homeline miniature circuit breaker with a 50 A, two-pole configuration and a 120/240 V AC rating. It provides Class A 6 mA GFCI protection with a 10 kA interrupting rating, uses plug-on mounting with a pigtail neutral, and is specified for Homeline electrical panels and CSEDs.

Technical Specifications

Product information and specifications for the selected item.

SKU: HOM250GFI

Product Information

BrandSquare D
MPNHOM250GFI
SKUHOM250GFI
UPC / GTIN00785901783572
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)50
Voltage120/240 V AC
Interruption TypeGFCI
Breaker TypeMiniature
Mounting TypePlug-On
Neutral Connection TypePigtail

Electrical Ratings

Maximum Amperage (A)50
Voltage120/240 V AC
Interruption TypeGFCI
Maximum load-conductor run250 (76), total one-way run ft (m)
GFCI protection limitationDoes not protect people who contact both power wires or either power wire and neutral
Supply-system requirementGrounded-neutral electrical systems only
GFCI test intervalTest after installation, then monthly
Short-circuit current rating10 kA
High-voltage test cautionMegger, high-voltage, and hi-pot tests can damage the GFCI; de-energize and isolate the breaker before testing
Class A ground-fault protection level6 mA
Ambient air temperature for operation104 (40) °F (°C)
HACR ratingHACR rated

Breaker Configuration

Breaker TypeMiniature
Mounting TypePlug-On
Neutral Connection TypePigtail
Series TypeHomeline
Panel spaces required2 spaces
Panel neutral wiringConnect the panel neutral wire to the load-center neutral bar for GFCI operation
Conductor sizeAluminum: 12–4; copper: 14–6 AWG
Reset procedureMove handle to OFF (O), then ON (I)
Incoming line connectionConnect the incoming line to the load-center bus
Panel compatibilityHomeline electrical panels and CSEDs
Range/dryer wiring cautionDo not connect to electric ranges or clothes dryers whose frames are grounded through a neutral conductor
Trip behaviorCommon trip
Terminal connectionScrew clamp terminals
Swimming-pool equipment cautionDo not connect to swimming-pool equipment installed before adoption of the 1965 National Electrical Code
Terminal tightening torque40.7 (4.6) lbf·in (N·m)
GFCI switching requirementBoth ungrounded (hot) conductors must be switched for ground-fault protection

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsCSA Certified, ROHS, UL Listed
RoHS substance statusCompliant with exemptions 7(a), 7(c)-I
Mercury contentMercury-free
Halogen contentHalogen-free product

Dimensions & Weight

Height (in.)4.22
Width (in.)1.98
Length (in.)3.07
Weight (lb.)1