Skip to content

Square D QO 25A 2-Pole Class A GFCI Circuit Breaker with Pigtail Neutral

0 Reviews
SKU
QO225GFI

The Square D QO225GFI is a QO-series miniature 25 A, two-pole Class A GFCI circuit breaker rated for 120/240 V AC. It has a 6 mA trip rating, a 10 kA interrupt rating, plug-in mounting, and a neutral pigtail.

  • 25 A, Two-Pole Rating
  • 120/240 V AC Rating
  • Class A GFCI, 6 mA Trip
  • 10 kA Interrupt Rating
  • QO-Series Plug-In Mounting
  • 18 in Neutral Pigtail

The Square D QO225GFI is a QO-series miniature 25 A, two-pole Class A GFCI circuit breaker rated for 120/240 V AC. It has a 6 mA trip rating, a 10 kA interrupt rating, plug-in mounting, and a neutral pigtail.

Product Overview

The Square D QO225GFI is a QO-series miniature 25 A, two-pole Class A GFCI circuit breaker rated for 120/240 V AC. It has a 6 mA trip rating, a 10 kA interrupt rating, plug-in mounting, and a neutral pigtail.

  • 25 A, Two-Pole Rating
  • 120/240 V AC Rating
  • Class A GFCI, 6 mA Trip
  • 10 kA Interrupt Rating
  • QO-Series Plug-In Mounting
  • 18 in Neutral Pigtail

Technical Specifications

Product information and specifications for the selected item.

SKU: QO225GFI

Product Information

BrandSquare D
MPNQO225GFI
SKUQO225GFI
UPC / GTIN785901562962
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)25
Voltage120/240 V AC
Interruption TypeGFCI
Breaker TypeMiniature
Mounting TypePlug-On
Neutral Connection TypePigtail

Electrical Ratings

Maximum Amperage (A)25
Voltage120/240 V AC
Interruption TypeGFCI
Supply system requirementUse only on grounded-neutral electrical systems
Maximum load-conductor run250 ft (76 m) maximum total one-way load-conductor run ft (m)
Operating-voltage thresholdMust be operational at 85% of rated voltage
Tightening torque35.4 lbf.in (4 N.m); 40.7 lbf.in (4.6 N.m) lbf.in (N.m)
Supported wire sizes14–8 AWG copper; 12–8 AWG aluminium
Ambient rating104 °F (40 °C) °F (°C)
Protection limitationDoes not protect people contacting both power wires or either power wire and neutral
Supported circuit configurationsThree-wire 120/240 Vac or 208Y/120 Vac; two-wire 240 Vac or 208 Vac; 120 Vac multiwire circuits

Breaker Configuration

Breaker TypeMiniature
Mounting TypePlug-On
Neutral Connection TypePigtail
Series TypeQO
Test-equipment restrictionMegger, high-voltage, or hi-pot tests can damage the GFCI; isolate the breaker before such tests
Trip indicationVisi-Trip indicates a trip; handle moves to the center tripped position
Terminal and conductor suitabilityPressure-plate terminals; single-wire terminations; suitable for 60°C or 75°C conductors
Hot-conductor switchingBoth ungrounded hot conductors must be switched for ground-fault protection
Line-side connectionIncoming line connects to the load-center bus
Application restrictionNot for use as a panelboard main breaker or in reverse-connected (backfed) applications
Reset procedureMove the handle to OFF, then ON, to reset
Panel neutral connection requirementConnect the panel neutral wire to the load-center or panelboard neutral bar for correct GFCI operation
Neutral pigtail lead length18 in (457 mm) in (mm)
Nuisance-trip application exclusionsDo not connect to pre-1965-NEC pool equipment or ranges/dryers whose frames are grounded through neutral
Panel spaces required2 spaces
GFCI test intervalTest after installation and monthly thereafter

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsCSA Certified, ROHS, UL Listed
TAA statusTAA compliant
REACH substance disclosureReference contains Substances of Very High Concern above the threshold
California Proposition 65 warningProp 65 warning identifies DINP (cancer) and DIDP (birth defects or reproductive harm)
EU RoHS statusCompliant by exemption

Dimensions & Weight

Height (in.)4.13
Width (in.)1.5
Length (in.)2.91
Weight (lb.)0.94

Product Documents

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.