QO250GFI

Square D QO250GFI is a QO-series, two-pole 50 A GFCI miniature circuit breaker rated for 120/240 V AC. It provides Class A 6 mA ground-fault protection with a 10 kA interrupting rating and has plug-on mounting with a pigtail neutral connection.

  • 50 A Two-Pole Rating
  • Class A 6 mA Ground-Fault Protection
  • 120/240 V AC Rating
  • 10 kA Interrupting Rating
  • QO Plug-On Mounting
  • Pigtail Neutral Connection

Square D QO250GFI is a QO-series, two-pole 50 A GFCI miniature circuit breaker rated for 120/240 V AC. It provides Class A 6 mA ground-fault protection with a 10 kA interrupting rating and has plug-on mounting with a pigtail neutral connection.

Product Overview

Square D QO250GFI is a QO-series, two-pole 50 A GFCI miniature circuit breaker rated for 120/240 V AC. It provides Class A 6 mA ground-fault protection with a 10 kA interrupting rating and has plug-on mounting with a pigtail neutral connection.

  • 50 A Two-Pole Rating
  • Class A 6 mA Ground-Fault Protection
  • 120/240 V AC Rating
  • 10 kA Interrupting Rating
  • QO Plug-On Mounting
  • Pigtail Neutral Connection

Technical Specifications

Product information and specifications for the selected item.

SKU: QO250GFI

Product Information

BrandSquare D
MPNQO250GFI
SKUQO250GFI
UPC / GTIN00785901764861
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)50
Voltage120/240 V AC
Interruption TypeGFCI
Breaker TypeMiniature
Mounting TypePlug-On
Neutral Connection TypePigtail

Electrical Ratings

Maximum Amperage (A)50
Voltage120/240 V AC
Interruption TypeGFCI
Interrupt rating10 kA at 120/240 V AC, 50/60 Hz
Conductor size12–4 aluminum; 14–6 copper AWG
High-frequency HVAC suitabilityHF ready for HVAC applications
Rated frequency50/60 Hz
Ambient rating104 °F (40 °C)
Ambient air temperature for operation40 °C

Breaker Configuration

Breaker TypeMiniature
Mounting TypePlug-On
Neutral Connection TypePigtail
Series TypeQO
Load-neutral wiring compatibilityWorks with or without a load neutral wire.
Test intervalTest after installation and monthly thereafter
Panel spaces2 spaces
Trip indicationVisi-Trip indication provides a clear visual signal when the breaker has tripped.
GFCI wiring requirementMust switch both ungrounded (hot) conductors; incoming line connects to the load-center bus
Supported circuit configurations3-wire 120/240 V or 208Y/120 V (15–50 A); 2-wire 240 V or 208 V; 120 V multiwire (15–50 A)
Electrical connection stylePressure plate
Neutral-system requirementUse only on a grounded-neutral system; connect the panel neutral wire to the load-center or panelboard neutral bar for correct GFCI operation
Load-conductor run limit250 total one-way ft (76 m)
Maximum total one-way load-conductor run250 ft
High-voltage test cautionMegger, high-voltage, or hi-pot tests will damage the GFCI; isolate the breaker before testing
Load-terminal tightening torque41 for load-neutral and load-power conductors in the 40–60 A range lb-in (4.6 N·m)

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsCSA Certified, ROHS, UL Listed
Warranty period18 months
REACH Annex XVII statusNo substances subject to REACH Annex XVII restrictions are used within the scope of restriction
REACH SVHC disclosureThe declaration identifies diboron trioxyde, lead monoxide (lead oxide), and lead among SVHCs above 0.1% at part level; each is listed in PCBA electronic components above the component threshold
EU RoHS statusCompliant by exemption
California Proposition 65 warningCancer and reproductive harm warning
Trade complianceTAA compliant

Dimensions & Weight

Height (in.)4.12
Width (in.)1.5
Length (in.)2.91
Weight (lb.)1.0009