586-554-2000
Mon–Fri 6:30am–5pm · Sat 8am–3pm
586-554-2000
Mon–Fri 6:30am–5pm
Square D QO250GFI is a QO-series, two-pole 50 A GFCI miniature circuit breaker rated for 120/240 V AC. It provides Class A 6 mA ground-fault protection with a 10 kA interrupting rating and has plug-on mounting with a pigtail neutral connection.
Square D QO250GFI is a QO-series, two-pole 50 A GFCI miniature circuit breaker rated for 120/240 V AC. It provides Class A 6 mA ground-fault protection with a 10 kA interrupting rating and has plug-on mounting with a pigtail neutral connection.
Square D QO250GFI is a QO-series, two-pole 50 A GFCI miniature circuit breaker rated for 120/240 V AC. It provides Class A 6 mA ground-fault protection with a 10 kA interrupting rating and has plug-on mounting with a pigtail neutral connection.
Product information and specifications for the selected item.
| Brand | Square D |
|---|---|
| MPN | QO250GFI |
| SKU | QO250GFI |
| UPC / GTIN | 00785901764861 |
| Category | Circuit Breakers |
| Maximum Amperage (A) | 50 |
|---|---|
| Voltage | 120/240 V AC |
| Interruption Type | GFCI |
| Breaker Type | Miniature |
| Mounting Type | Plug-On |
| Neutral Connection Type | Pigtail |
| Maximum Amperage (A) | 50 |
|---|---|
| Voltage | 120/240 V AC |
| Interruption Type | GFCI |
| Interrupt rating | 10 kA at 120/240 V AC, 50/60 Hz |
| Conductor size | 12–4 aluminum; 14–6 copper AWG |
| High-frequency HVAC suitability | HF ready for HVAC applications |
| Rated frequency | 50/60 Hz |
| Ambient rating | 104 °F (40 °C) |
| Ambient air temperature for operation | 40 °C |
| Breaker Type | Miniature |
|---|---|
| Mounting Type | Plug-On |
| Neutral Connection Type | Pigtail |
| Series Type | QO |
| Load-neutral wiring compatibility | Works with or without a load neutral wire. |
| Test interval | Test after installation and monthly thereafter |
| Panel spaces | 2 spaces |
| Trip indication | Visi-Trip indication provides a clear visual signal when the breaker has tripped. |
| GFCI wiring requirement | Must switch both ungrounded (hot) conductors; incoming line connects to the load-center bus |
| Supported circuit configurations | 3-wire 120/240 V or 208Y/120 V (15–50 A); 2-wire 240 V or 208 V; 120 V multiwire (15–50 A) |
| Electrical connection style | Pressure plate |
| Neutral-system requirement | Use only on a grounded-neutral system; connect the panel neutral wire to the load-center or panelboard neutral bar for correct GFCI operation |
| Load-conductor run limit | 250 total one-way ft (76 m) |
| Maximum total one-way load-conductor run | 250 ft |
| High-voltage test caution | Megger, high-voltage, or hi-pot tests will damage the GFCI; isolate the breaker before testing |
| Load-terminal tightening torque | 41 for load-neutral and load-power conductors in the 40–60 A range lb-in (4.6 N·m) |
| Bundle/Single | Single Product |
|---|---|
| Pack Options | Single Item |
| Certifications and Listings | CSA Certified, ROHS, UL Listed |
|---|---|
| Warranty period | 18 months |
| REACH Annex XVII status | No substances subject to REACH Annex XVII restrictions are used within the scope of restriction |
| REACH SVHC disclosure | The declaration identifies diboron trioxyde, lead monoxide (lead oxide), and lead among SVHCs above 0.1% at part level; each is listed in PCBA electronic components above the component threshold |
| EU RoHS status | Compliant by exemption |
| California Proposition 65 warning | Cancer and reproductive harm warning |
| Trade compliance | TAA compliant |
| Height (in.) | 4.12 |
|---|---|
| Width (in.) | 1.5 |
| Length (in.) | 2.91 |
| Weight (lb.) | 1.0009 |
Added to cart