The Square D QO Qwik-Gard QO215GFI is a 15 A, two-pole common-trip GFCI breaker rated for 120/240 V AC, with Class A 6 mA ground-fault protection and a 10 kA interrupting rating. It uses plug-on mounting with a pigtail neutral and fits standard QO and QO plug-on-neutral load centers.
The Square D QO Qwik-Gard QO215GFI is a 15 A, two-pole common-trip GFCI breaker rated for 120/240 V AC, with Class A 6 mA ground-fault protection and a 10 kA interrupting rating. It uses plug-on mounting with a pigtail neutral and fits standard QO and QO plug-on-neutral load centers.
The Square D QO Qwik-Gard QO215GFI is a 15 A, two-pole common-trip GFCI breaker rated for 120/240 V AC, with Class A 6 mA ground-fault protection and a 10 kA interrupting rating. It uses plug-on mounting with a pigtail neutral and fits standard QO and QO plug-on-neutral load centers.
Product information and specifications for the selected item.
| Brand | Square D |
|---|---|
| MPN | QO215GFI |
| SKU | QO215GFI |
| UPC / GTIN | 00785901562986 |
| Category | Circuit Breakers |
| Maximum Amperage (A) | 15 |
|---|---|
| Voltage | 120/240 V AC |
| Interruption Type | GFCI |
| Breaker Type | Miniature |
| Mounting Type | Plug-On |
| Neutral Connection Type | Pigtail |
| Maximum Amperage (A) | 15 |
|---|---|
| Voltage | 120/240 V AC |
| Interruption Type | GFCI |
| Interrupting rating | 10 at 120/240 V AC; 10 at 120 V AC, 50/60 Hz kA |
| Conductor temperature suitability | Suitable for use with 60 °C or 75 °C conductors |
| Class A ground-fault sensitivity | 6 mA |
| Additional protection functions | Overload and short-circuit protection |
| Maximum one-way load-conductor run | 250 ft |
| Ambient rating | 104 (40) °F (°C) |
| Breaker Type | Miniature |
|---|---|
| Mounting Type | Plug-On |
| Neutral Connection Type | Pigtail |
| Series Type | QO |
| Terminal tightening torque | 35.4 (4); 40.7 (4.6) lbf·in (N·m) |
| Electrical connection | Pressure plate |
| Compatible load centers | Fits standard QO and QO plug-on-neutral load centers |
| Panel spaces required | 2 spaces |
| Load-terminal wire range | 14–8 copper; 12–8 aluminum AWG |
| Load-neutral wiring | Works with or without a load-neutral wire; the neutral pigtail must still connect to the panel neutral |
| Terminal configuration | Pressure-plate terminals; single-wire termination |
| Trip configuration | Common trip |
| Supported conductor sizes | Copper: 14–8; aluminum: 12–8 AWG |
| Backfeed restriction | Not suitable for backfed operation |
| Compatible equipment | QO load centers; NQOD and NQ panelboards; NQOD and NQ OEM interiors; Speed-D switchboard distribution panels |
| Bundle/Single | Single Product |
|---|---|
| Pack Options | Single Item |
| Certifications and Listings | CSA Certified, ROHS, UL Listed |
|---|---|
| Total lifecycle carbon footprint | 41 kg CO2 eq. |
| California Proposition 65 warning | Warning identifies DINP (cancer) and DIDP (birth defects or other reproductive harm) |
| REACH status | Reference contains substances of very high concern above the threshold |
| EU RoHS status | Compliant by exemption |
| TAA status | Compliant |
| Recyclability potential | 31 % |
| Mercury-free | Yes |
| Height (in.) | 4.13 |
|---|---|
| Width (in.) | 1.5 |
| Length (in.) | 2.91 |
| Weight (lb.) | 0.95 |