| Brand | Generac |
|---|---|
| MPN | RG04845ANAXSD |
| SKU | RG04845ANAXSD |
| Category | Commercial Standby Generators |
| Running Wattage | 48000 W |
|---|---|
| Output Voltage | 120/240 VAC |
| Electrical Phases | 1 |
| Fuel Type | Liquid Propane, Natural Gas |
| Running Wattage | 48000 W |
|---|---|
| Output Voltage | 120/240 VAC |
| Electrical Phases | 1 |
| Alternator design and insulation | Synchronous alternator; Class H rotor and stator insulation |
| Altitude derating | 3% per 1,000 ft above 600 ft (1% per 100 m above 183 m) |
| Temperature derating | 1.7% per 10 °F above 77 °F (1.5% per 5 °C above 25 °C) |
| Fuel Type | Liquid Propane, Natural Gas |
|---|---|
| Minimum fuel heating value | Natural gas: at least 1,000 (37.26 MJ/mÂł); LP: at least 2,520 (93.8 MJ/mÂł) BTU/ftÂł |
| Fuel inlet pressure range | LP vapor: 7–14 (1.74–3.48 kPa); natural gas: 3.5–14 (0.87–3.48 kPa) in H2O |
| LP consumption at full load | 6.6 (25.0 L/h) at 100% rated load US gph |
| Natural gas consumption at full load | 607 (17.2 mÂł/h) at 100% rated load cfh |
| Engine Brand | Generac |
|---|---|
| Cooling Type | Liquid Cooled |
| RPM | 1800 rpm |
| Coolant capacity | 2.9 (11 L) US gal |
| Maximum ambient air temperature | 122 (50 °C) °F |
| Coolant specification | 50/50 mixture (50% ethylene glycol) |
| Compression ratio | 9.9:1 |
| Engine configuration | Generac 4.5 L inline 4-cylinder, naturally aspirated |
| Engine speeds | Exercise: 1,500; operating: 1,800 rpm |
| Crankcase oil capacity | 12 (11 L) qt |
| Generator Features | Automatic Voltage Regulation, Hour Meter, Low Oil Alert/Shutdown |
|---|---|
| Features | Approved for Commercial Use, EPA Compliant |
| Approved for Commercial Use | Yes |
| Generator listing | UL 2200 listed |
| Enclosure color | Bisque |
| Fuel line connection | 1-1/4 in. NPT female tee through baseframe opening |
| Wind speed rating | 115 (185 km/h); requires a correctly prepared concrete pad and anchoring system mph |
| Enclosure material | Corrosion-resistant aluminum |
| Battery charging system | 12 V system; 35 A charge alternator; 2.5 A battery charger |
| Emissions certification | EPA emissions certified |
| Battery compatibility | Recommended: flooded lead-acid Group 27, 600 CCA minimum; maximum: flooded lead-acid Group 31, 750 CCA minimum |
| Height (in.) | 46 |
|---|---|
| Width (in.) | 33.5 |
| Length (in.) | 83.4 |
| Weight (lb.) | 1781 |
| Recommended mounting bolt diameter | 1/2 in |
| SwRI-listed structure clearance | As close as 18 in (457 mm) to a structure; keep away from doors, windows, and fresh-air intakes and follow local codes. |